smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
Device Model: WDC WD40EFRX-68N32N0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 82.00A82
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jun 3 10:32:32 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (43080) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 457) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x303d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 199 161 021 - 5041
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 116
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 078 078 000 - 16763
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 115
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 94
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 13595
|
||||
194 Temperature_Celsius -O---K 117 111 000 - 33
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 56 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 93 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/37 Celsius
|
||||
Lifetime Min/Max Temperature: 21/39 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/65 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (254)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 115 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 16763 --- Power-on Hours
|
||||
0x01 0x018 6 68317722242 --- Logical Sectors Written
|
||||
0x01 0x020 6 890037261 --- Number of Write Commands
|
||||
0x01 0x028 6 489821359362 --- Logical Sectors Read
|
||||
0x01 0x030 6 2001670815 --- Number of Read Commands
|
||||
0x01 0x038 6 217257856 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 16690 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 15904 --- Head Flying Hours
|
||||
0x03 0x018 4 13690 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 94 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 65537 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x018 1 33 --- Average Long Term Temperature
|
||||
0x05 0x020 1 39 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 37 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 34 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 28 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 65 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 685 --- Number of Hardware Resets
|
||||
0x06 0x010 4 580 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 841920 Vendor specific
|
||||
|
||||
|
||||
|
220
HDD/WDC/WD40/WD40EFRX-68N32N0/64AD6894A92D
Normal file
220
HDD/WDC/WD40/WD40EFRX-68N32N0/64AD6894A92D
Normal file
@@ -0,0 +1,220 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
Device Model: WDC WD40EFRX-68N32N0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 82.00A82
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jun 3 10:32:32 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (46620) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 495) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x303d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 199 162 021 - 5050
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 117
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 078 078 000 - 16784
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 116
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 94
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 15575
|
||||
194 Temperature_Celsius -O---K 118 112 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 56 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 93 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/36 Celsius
|
||||
Lifetime Min/Max Temperature: 21/38 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/65 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (132)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 116 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 16784 --- Power-on Hours
|
||||
0x01 0x018 6 71748653829 --- Logical Sectors Written
|
||||
0x01 0x020 6 902913656 --- Number of Write Commands
|
||||
0x01 0x028 6 492462417743 --- Logical Sectors Read
|
||||
0x01 0x030 6 2008244694 --- Number of Read Commands
|
||||
0x01 0x038 6 292857856 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 16712 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 15824 --- Head Flying Hours
|
||||
0x03 0x018 4 15670 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 2 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 94 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 65537 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 32 --- Average Short Term Temperature
|
||||
0x05 0x018 1 32 --- Average Long Term Temperature
|
||||
0x05 0x020 1 38 --- Highest Temperature
|
||||
0x05 0x028 1 24 --- Lowest Temperature
|
||||
0x05 0x030 1 37 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 33 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 28 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 65 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 709 --- Number of Hardware Resets
|
||||
0x06 0x010 4 586 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 841920 Vendor specific
|
||||
|
||||
|
||||
|
227
HDD/WDC/WD40/WD40EFRX-68N32N0/8B17F0B036ED
Normal file
227
HDD/WDC/WD40/WD40EFRX-68N32N0/8B17F0B036ED
Normal file
@@ -0,0 +1,227 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
Device Model: WDC WD40EFRX-68N32N0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 82.00A82
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jun 14 20:50:30 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (45840) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 486) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x303d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 186 166 021 - 5675
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 33
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 14650
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 33
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 18
|
||||
193 Load_Cycle_Count -O--CK 198 198 000 - 8822
|
||||
194 Temperature_Celsius -O---K 118 110 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 56 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 93 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 14225 -
|
||||
# 2 Short offline Completed without error 00% 9893 -
|
||||
# 3 Short offline Completed without error 00% 5367 -
|
||||
# 4 Short offline Completed without error 00% 4864 -
|
||||
# 5 Short offline Completed without error 00% 4344 -
|
||||
# 6 Short offline Completed without error 00% 1740 -
|
||||
# 7 Short offline Completed without error 00% 1235 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/38 Celsius
|
||||
Lifetime Min/Max Temperature: 20/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/65 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (256)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 33 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14650 --- Power-on Hours
|
||||
0x01 0x018 6 12285204944 --- Logical Sectors Written
|
||||
0x01 0x020 6 178431648 --- Number of Write Commands
|
||||
0x01 0x028 6 41774796809 --- Logical Sectors Read
|
||||
0x01 0x030 6 225306220 --- Number of Read Commands
|
||||
0x01 0x038 6 1200392448 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 14618 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 13158 --- Head Flying Hours
|
||||
0x03 0x018 4 8841 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 12 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 18 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 30 --- Average Short Term Temperature
|
||||
0x05 0x018 1 32 --- Average Long Term Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 24 --- Lowest Temperature
|
||||
0x05 0x030 1 37 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 33 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 27 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 65 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 496 --- Number of Hardware Resets
|
||||
0x06 0x010 4 321 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 12 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 16 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 2536781 Vendor specific
|
||||
|
||||
|
||||
|
217
HDD/WDC/WD40/WD40EZRZ-00GXCB0/A91572C9894A
Normal file
217
HDD/WDC/WD40/WD40EZRZ-00GXCB0/A91572C9894A
Normal file
@@ -0,0 +1,217 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue
|
||||
Device Model: WDC WD40EZRZ-00GXCB0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 80.00A80
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Jun 15 18:47:44 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (43560) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 463) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 165 162 021 - 6733
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 222
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 5521
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 221
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 28
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 635235
|
||||
194 Temperature_Celsius -O---K 103 100 000 - 47
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 56 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 93 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/47 Celsius
|
||||
Lifetime Min/Max Temperature: 19/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (477)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 221 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 5521 --- Power-on Hours
|
||||
0x01 0x018 6 37845949824 --- Logical Sectors Written
|
||||
0x01 0x020 6 274210682 --- Number of Write Commands
|
||||
0x01 0x028 6 39092742774 --- Logical Sectors Read
|
||||
0x01 0x030 6 467305126 --- Number of Read Commands
|
||||
0x01 0x038 6 2695730816 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 5499 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 4069 --- Head Flying Hours
|
||||
0x03 0x018 4 635264 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 28 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 47 --- Current Temperature
|
||||
0x05 0x010 1 45 --- Average Short Term Temperature
|
||||
0x05 0x018 1 42 --- Average Long Term Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x030 1 47 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 42 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 32 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 2551 --- Number of Hardware Resets
|
||||
0x06 0x010 4 2033 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 88991 Vendor specific
|
||||
|
||||
|
||||
|
223
HDD/WDC/WD40/WD40PURZ-85TTDY0/FEF60F8F54CE
Normal file
223
HDD/WDC/WD40/WD40PURZ-85TTDY0/FEF60F8F54CE
Normal file
@@ -0,0 +1,223 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: WDC WD40PURZ-85TTDY0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 80.00A80
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 3 08:32:20 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (43740) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 464) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x303d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 253 051 - 0
|
||||
3 Spin_Up_Time POS--K 100 253 021 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 24
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1
|
||||
194 Temperature_Celsius -O---K 119 115 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 56 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 93 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/35 Celsius
|
||||
Lifetime Min/Max Temperature: 21/35 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/65 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (56)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 24 --- Power-on Hours
|
||||
0x01 0x018 6 4 --- Logical Sectors Written
|
||||
0x01 0x020 6 0 --- Number of Write Commands
|
||||
0x01 0x028 6 37654 --- Logical Sectors Read
|
||||
0x01 0x030 6 15 --- Number of Read Commands
|
||||
0x01 0x038 6 86400000 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 24 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 24 --- Head Flying Hours
|
||||
0x03 0x018 4 1 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x010 1 31 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 35 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 31 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 31 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 65 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 89341 Vendor specific
|
||||
|
||||
|
||||
|
Reference in New Issue