mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 129, modified: 0)
This commit is contained in:
220
SSD/Crucial/CT500/CT500MX200SSD1/4769EA7F02F4
Normal file
220
SSD/Crucial/CT500/CT500MX200SSD1/4769EA7F02F4
Normal file
@@ -0,0 +1,220 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Crucial_CT500MX200SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU01
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 9 02:35:50 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1325) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 7) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 8288
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1348
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 096 096 000 - 138
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 124
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 5552
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 071 053 000 - 29 (Min/Max 17/47)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain P---CK 096 096 000 - 4
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_Host_Sector_Write -O--CK 100 100 000 - 57128611629
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 1789075686
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 2140233776
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 16000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 16000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 8245 -
|
||||
# 2 Short offline Completed without error 00% 8238 -
|
||||
# 3 Short offline Completed without error 00% 8211 -
|
||||
# 4 Short offline Completed without error 00% 6819 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 1617 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 1587 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 1525 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 1462 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 1399 -
|
||||
#10 Vendor (0xff) Completed without error 00% 1337 -
|
||||
#11 Vendor (0xff) Completed without error 00% 1274 -
|
||||
#12 Vendor (0xff) Completed without error 00% 1212 -
|
||||
#13 Vendor (0xff) Completed without error 00% 1149 -
|
||||
#14 Vendor (0xff) Completed without error 00% 1086 -
|
||||
#15 Vendor (0xff) Completed without error 00% 1023 -
|
||||
#16 Vendor (0xff) Completed without error 00% 961 -
|
||||
#17 Vendor (0xff) Completed without error 00% 855 -
|
||||
#18 Vendor (0xff) Completed without error 00% 835 -
|
||||
#19 Vendor (0xff) Completed without error 00% 671 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/30 Celsius
|
||||
Lifetime Min/Max Temperature: 17/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (414)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1348 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 8288 --- Power-on Hours
|
||||
0x01 0x018 6 57128611629 --- Logical Sectors Written
|
||||
0x01 0x020 6 1318196482 --- Number of Write Commands
|
||||
0x01 0x028 6 35390209436 --- Logical Sectors Read
|
||||
0x01 0x030 6 461240730 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1305 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 29 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 32 --- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x030 1 39 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 18 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 37 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 9461 --- Number of Hardware Resets
|
||||
0x06 0x010 4 1564 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 16 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
@@ -28,9 +28,9 @@ MTBF — avg. MTBF in years per sample.
|
||||
| Crucial | CT1050MX300SSD1 | 1 TB | 1 | 811 | 0 | 2.22 |
|
||||
| Crucial | M4-CT064M4SSD2 | 64 GB | 1 | 589 | 0 | 1.61 |
|
||||
| Crucial | CT250MX200SSD1 | 250 GB | 2 | 517 | 0 | 1.42 |
|
||||
| Crucial | CT500MX200SSD1 | 500 GB | 2 | 199 | 0 | 0.55 |
|
||||
| Crucial | CT120BX300SSD1 | 120 GB | 1 | 108 | 0 | 0.30 |
|
||||
| Crucial | CT525MX300SSD1 | 528 GB | 1 | 300 | 2 | 0.27 |
|
||||
| Crucial | CT500MX200SSD1 | 500 GB | 1 | 54 | 0 | 0.15 |
|
||||
| Crucial | CT120BX500SSD1 | 120 GB | 1 | 14 | 0 | 0.04 |
|
||||
|
||||
SSD by Family
|
||||
@@ -48,4 +48,4 @@ MTBF — avg. MTBF in years per sample.
|
||||
|-----------|------------------------|--------|---------|-------|-------|--------|
|
||||
| Crucial | Unknown | 1 | 2 | 1042 | 0 | 2.86 |
|
||||
| Crucial | RealSSD m4/C400/P400 | 1 | 1 | 589 | 0 | 1.61 |
|
||||
| Crucial | BX/MX1/2/3/500, M5/... | 7 | 8 | 405 | 1 | 1.04 |
|
||||
| Crucial | BX/MX1/2/3/500, M5/... | 7 | 9 | 398 | 1 | 1.03 |
|
||||
|
Reference in New Issue
Block a user