smartctl 7.0 2018-12-30 r4883 [x86_64-unknown-openbsd6.6] (local build)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: PLEXTOR PX-256M8VG
Serial Number: --
LU WWN Device Id: 5 002303 ...
Firmware Version: 1.01
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: M.2
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Jun 9 22:37:10 2020 -05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0
5 Reallocated_Sector_Ct 0x0003 100 100 000 Pre-fail Always - 0
9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 5532
12 Power_Cycle_Count 0x0003 100 100 000 Pre-fail Always - 685
170 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
171 Unknown_Attribute 0x0003 100 100 000 Pre-fail Always - 0
172 Unknown_Attribute 0x0003 100 100 000 Pre-fail Always - 0
173 Unknown_Attribute 0x0003 100 100 000 Pre-fail Always - 33
174 Unknown_Attribute 0x0003 100 100 000 Pre-fail Always - 45
175 Program_Fail_Count_Chip 0x0003 100 100 000 Pre-fail Always - 0
176 Erase_Fail_Count_Chip 0x0003 100 100 000 Pre-fail Always - 0
178 Used_Rsvd_Blk_Cnt_Chip 0x0003 100 100 000 Pre-fail Always - 0
179 Used_Rsvd_Blk_Cnt_Tot 0x0003 100 100 000 Pre-fail Always - 0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0033 100 100 005 Pre-fail Always - 99
181 Program_Fail_Cnt_Total 0x0003 100 100 000 Pre-fail Always - 0
182 Erase_Fail_Count_Total 0x0003 100 100 000 Pre-fail Always - 0
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 24
194 Temperature_Celsius 0x0002 100 100 000 Old_age Always - 29
195 Hardware_ECC_Recovered 0x0003 100 100 000 Pre-fail Always - 0
199 UDMA_CRC_Error_Count 0x0003 100 100 000 Pre-fail Always - 0
232 Available_Reservd_Space 0x0003 100 100 010 Pre-fail Always - 100
233 Media_Wearout_Indicator 0x0003 100 100 000 Pre-fail Always - 8685
241 Total_LBAs_Written 0x0003 100 100 000 Pre-fail Always - 210664
242 Total_LBAs_Read 0x0003 100 100 000 Pre-fail Always - 28057
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 0
Warning: ATA Specification requires self-test log structure revision number = 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported