1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 321, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2020-06-01 15:47:06 +03:00
parent e9f946b4e5
commit fe1dcd6109
361 changed files with 60080 additions and 2 deletions

View File

@@ -0,0 +1,100 @@
smartctl 6.6 2017-11-05 r4594 [MidnightBSD 1.2 amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Desktop HDD.15
Device Model: ST5000DM000-1FK178
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: CC41
User Capacity: 5,000,981,078,016 bytes [5.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5980 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri May 22 12:06:36 2020 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 642) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3025) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 114 100 006 Pre-fail Always - 71450288
3 Spin_Up_Time 0x0003 092 091 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 067 067 020 Old_age Always - 34050
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 082 060 030 Pre-fail Always - 48942441472
9 Power_On_Hours 0x0032 062 062 000 Old_age Always - 33288
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 067 067 020 Old_age Always - 34053
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 098 000 Old_age Always - 7 7 36
189 High_Fly_Writes 0x003a 094 094 000 Old_age Always - 6
190 Airflow_Temperature_Cel 0x0022 060 048 045 Old_age Always - 40 (Min/Max 35/43)
194 Temperature_Celsius 0x0022 040 052 000 Old_age Always - 40 (0 18 0 0 0)
195 Hardware_ECC_Recovered 0x001a 114 100 000 Old_age Always - 71450288
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 25439h+43m+46.678s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 62890329714
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 12550340456329
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 18966 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.