1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 321, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2020-06-01 15:47:06 +03:00
parent e9f946b4e5
commit fe1dcd6109
361 changed files with 60080 additions and 2 deletions

View File

@@ -0,0 +1,118 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar SE Serial ATA
Device Model: WDC WD1600JD-00GBB0
Serial Number: --
Firmware Version: 02.05D02
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
Local Time is: Mon May 25 14:01:48 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5061) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 200 200 051 - 0
3 Spin_Up_Time POS--- 145 142 021 - 3275
4 Start_Stop_Count -O--CK 100 100 040 - 383
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate PO-R-- 200 200 051 - 0
9 Power_On_Hours -O--CK 001 001 000 - 127515
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 381
194 Temperature_Celsius -O---K 127 253 000 - 23
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable -O--C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 2
200 Multi_Zone_Error_Rate P--R-- 200 155 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 796 -
# 2 Extended offline Completed without error 00% 340 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,118 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar SE Serial ATA
Device Model: WDC WD1600JD-00GBB0
Serial Number: --
Firmware Version: 02.05D02
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
Local Time is: Mon May 25 14:01:47 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5067) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 200 200 051 - 0
3 Spin_Up_Time POS--- 149 145 021 - 3075
4 Start_Stop_Count -O--CK 100 100 040 - 383
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate PO-R-- 200 200 051 - 0
9 Power_On_Hours -O--CK 001 001 000 - 127415
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 381
194 Temperature_Celsius -O---K 127 253 000 - 23
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable -O--C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 2
200 Multi_Zone_Error_Rate P--R-- 200 155 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 689 -
# 2 Extended offline Completed without error 00% 228 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,119 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar SE Serial ATA
Device Model: WDC WD1600JD-00GBB0
Serial Number: --
Firmware Version: 02.05D02
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
Local Time is: Mon May 25 14:01:46 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5073) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 200 200 051 - 0
3 Spin_Up_Time POS--- 148 145 021 - 3125
4 Start_Stop_Count -O--CK 100 100 040 - 384
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate PO-R-- 200 200 051 - 0
9 Power_On_Hours -O--CK 001 001 000 - 127422
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 382
194 Temperature_Celsius -O---K 125 253 000 - 25
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable -O--C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 0
200 Multi_Zone_Error_Rate P--R-- 200 155 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 702 -
# 2 Extended offline Completed without error 00% 242 -
# 3 Extended offline Completed without error 00% 360 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,118 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar SE Serial ATA
Device Model: WDC WD1600JD-00GBB0
Serial Number: --
Firmware Version: 02.05D02
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
Local Time is: Mon May 25 14:01:47 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5061) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 200 200 051 - 0
3 Spin_Up_Time POS--- 149 143 021 - 3083
4 Start_Stop_Count -O--CK 100 100 040 - 380
5 Reallocated_Sector_Ct PO--CK 199 199 140 - 9
7 Seek_Error_Rate PO-R-- 200 200 051 - 0
9 Power_On_Hours -O--CK 001 001 000 - 127774
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 379
194 Temperature_Celsius -O---K 124 253 000 - 26
196 Reallocated_Event_Count -O--CK 194 194 000 - 6
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable -O--C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 0
200 Multi_Zone_Error_Rate P--R-- 200 155 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 1050 -
# 2 Extended offline Completed without error 00% 582 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported