mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 321, modified: 0)
This commit is contained in:
224
SSD/Crucial/CT1050/CT1050MX300SSD1/648ECCD7B1AA
Normal file
224
SSD/Crucial/CT1050/CT1050MX300SSD1/648ECCD7B1AA
Normal file
@@ -0,0 +1,224 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Crucial_CT1050MX300SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0CR060
|
||||
User Capacity: 1,050,214,588,416 bytes [1.05 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 27 10:39:01 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x04) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1366) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 10) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 19472
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 28
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 092 092 000 - 120
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 16
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 064 058 000 - 36 (Min/Max 19/42)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 092 092 001 - 8
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 100124183874
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 3128880753
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 1555913852
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 4404
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 17495 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 17280 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 16973 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 1241 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 16283 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 15814 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 15472 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 15160 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 14833 -
|
||||
#10 Vendor (0xff) Completed without error 00% 14444 -
|
||||
#11 Vendor (0xff) Completed without error 00% 13933 -
|
||||
#12 Vendor (0xff) Completed without error 00% 13491 -
|
||||
#13 Vendor (0xff) Completed without error 00% 13080 -
|
||||
#14 Vendor (0xff) Completed without error 00% 11620 -
|
||||
#15 Vendor (0xff) Completed without error 00% 10409 -
|
||||
#16 Vendor (0xff) Completed without error 00% 10116 -
|
||||
#17 Vendor (0xff) Completed without error 00% 10090 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/42 Celsius
|
||||
Lifetime Min/Max Temperature: 19/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (255)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 28 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19472 --- Power-on Hours
|
||||
0x01 0x018 6 100124183874 --- Logical Sectors Written
|
||||
0x01 0x020 6 1700708260 --- Number of Write Commands
|
||||
0x01 0x028 6 23383556502 --- Logical Sectors Read
|
||||
0x01 0x030 6 949967649 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 29 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 42 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x030 1 35 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 328 --- Number of Hardware Resets
|
||||
0x06 0x010 4 63 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 8 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 24 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
155
SSD/Crucial/CT120/CT120BX300SSD1/EBE522823790
Normal file
155
SSD/Crucial/CT120/CT120BX300SSD1/EBE522823790
Normal file
@@ -0,0 +1,155 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: CT120BX300SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: M2CR021
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon May 25 13:57:19 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 30) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 2592
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 52
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 090 090 000 - 161
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 22
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 74
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 1
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 046 038 000 - 54 (Min/Max 0/62)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 090 090 001 - 10
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 7503236960
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 120259414
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 441103053
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 64 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Completed [00% left] (0-65535)
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 54 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/62 Celsius
|
||||
Lifetime Min/Max Temperature: 0/62 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/100 Celsius
|
||||
Min/Max Temperature Limit: 0/100 Celsius
|
||||
Temperature History Size (Index): 128 (51)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
|
||||
|
144
SSD/Crucial/CT120/CT120BX500SSD1/4E80C9ADAF10
Normal file
144
SSD/Crucial/CT120/CT120BX500SSD1/4E80C9ADAF10
Normal file
@@ -0,0 +1,144 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: CT120BX500SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: M6CR013
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 13:04:44 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 120) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x11) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 10) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 050 - 338
|
||||
12 Power_Cycle_Count -O--CK 100 100 050 - 3
|
||||
171 Program_Fail_Count -O--CK 100 100 050 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 050 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 100 100 050 - 1
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 050 - 1
|
||||
180 Unused_Reserve_NAND_Blk -O--CK 100 100 050 - 100
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 050 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 050 - 0
|
||||
194 Temperature_Celsius -O---K 067 051 050 - 33 (Min/Max 30/49)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 050 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 050 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 050 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 100 100 001 - 100
|
||||
206 Write_Error_Rate -OSR-K 100 100 050 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 050 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 050 - 94282154
|
||||
247 Host_Program_Page_Count -O--CK 100 100 050 - 2946317
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 050 - 1308672
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 32 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
Selective Self-tests/Logging not supported
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 3 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 338 --- Power-on Hours
|
||||
0x01 0x018 6 94282154 --- Logical Sectors Written
|
||||
0x01 0x020 6 825880 --- Number of Write Commands
|
||||
0x01 0x028 6 131368178 --- Logical Sectors Read
|
||||
0x01 0x030 6 4630552 --- Number of Read Commands
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
220
SSD/Crucial/CT240/CT240M500SSD3/2883DE3FC7A5
Normal file
220
SSD/Crucial/CT240/CT240M500SSD3/2883DE3FC7A5
Normal file
@@ -0,0 +1,220 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Crucial_CT240M500SSD3
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU05
|
||||
User Capacity: 240,057,409,536 bytes [240 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: < 1.8 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon May 25 11:36:37 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1115) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 18) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 22031
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 8948
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 099 099 000 - 42
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 74
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 4066
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 054 037 000 - 46 (Min/Max 0/63)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain P---CK 099 099 000 - 1
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 --- - 9873813277
|
||||
247 Host_Program_Page_Count -O--CK 100 100 --- - 308575643
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 --- - 237862191
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 255 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 429 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 145 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 20234 -
|
||||
# 2 Extended offline Completed without error 00% 15704 -
|
||||
# 3 Extended offline Completed without error 00% 15441 -
|
||||
# 4 Extended captive Interrupted (host reset) 00% 15436 -
|
||||
# 5 Short captive Completed without error 00% 15436 -
|
||||
# 6 Short offline Completed without error 00% 11334 -
|
||||
# 7 Short offline Completed without error 00% 10632 -
|
||||
# 8 Extended offline Completed without error 00% 10442 -
|
||||
# 9 Short offline Completed without error 00% 8368 -
|
||||
#10 Offline Completed without error 00% 7628 -
|
||||
#11 Offline Completed without error 00% 7627 -
|
||||
#12 Offline Completed without error 00% 7627 -
|
||||
#13 Offline Completed without error 00% 7627 -
|
||||
#14 Offline Completed without error 00% 7627 -
|
||||
#15 Offline Completed without error 00% 7627 -
|
||||
#16 Offline Completed without error 00% 7627 -
|
||||
#17 Vendor (0xff) Completed without error 00% 5340 -
|
||||
#18 Short offline Completed without error 00% 5339 -
|
||||
#19 Short offline Completed without error 00% 4744 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/46 Celsius
|
||||
Lifetime Min/Max Temperature: 0/63 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (29)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 8948 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 22031 --- Power-on Hours
|
||||
0x01 0x018 6 9873813277 --- Logical Sectors Written
|
||||
0x01 0x020 6 133565163 --- Number of Write Commands
|
||||
0x01 0x028 6 17811991733 --- Logical Sectors Read
|
||||
0x01 0x030 6 492947190 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 8902 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 46 --- Current Temperature
|
||||
0x05 0x010 1 45 --- Average Short Term Temperature
|
||||
0x05 0x018 1 45 --- Average Long Term Temperature
|
||||
0x05 0x020 1 63 --- Highest Temperature
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x030 1 54 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 32 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 49 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 43 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 - --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1115 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
214
SSD/Crucial/CT250/CT250MX200SSD1/1DBA3C9B0868
Normal file
214
SSD/Crucial/CT250/CT250MX200SSD1/1DBA3C9B0868
Normal file
@@ -0,0 +1,214 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Crucial_CT250MX200SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU02
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 09:11:09 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 795) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 3124
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1959
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 74
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 30
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2593
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 3
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 070 048 000 - 30 (Min/Max 17/52)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 18977921529
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 593061801
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 334502269
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 16000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 16000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 2818 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 2655 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 1845 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 1377 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 1305 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 1178 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 1159 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 1096 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 979 -
|
||||
#10 Vendor (0xff) Completed without error 00% 193 -
|
||||
#11 Vendor (0xff) Completed without error 00% 173 -
|
||||
#12 Vendor (0xff) Completed without error 00% 93 -
|
||||
#13 Vendor (0xff) Completed without error 00% 13 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/30 Celsius
|
||||
Lifetime Min/Max Temperature: 17/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (9)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1959 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3124 --- Power-on Hours
|
||||
0x01 0x018 6 18977921529 --- Logical Sectors Written
|
||||
0x01 0x020 6 163112764 --- Number of Write Commands
|
||||
0x01 0x028 6 6795274527 --- Logical Sectors Read
|
||||
0x01 0x030 6 68247566 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1954 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 30 --- Average Short Term Temperature
|
||||
0x05 0x018 1 33 --- Average Long Term Temperature
|
||||
0x05 0x020 1 52 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x030 1 42 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 33 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 32 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 8684 --- Number of Hardware Resets
|
||||
0x06 0x010 4 894 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
220
SSD/Crucial/CT250/CT250MX200SSD1/9B6FE8DB248D
Normal file
220
SSD/Crucial/CT250/CT250MX200SSD1/9B6FE8DB248D
Normal file
@@ -0,0 +1,220 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Crucial_CT250MX200SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU03
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 20:20:52 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 795) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 21731
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 229
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 055 055 000 - 1378
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 34
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2604
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 51
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 051 040 000 - 49 (Min/Max 18/60)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 055 055 001 - 45
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 104879850588
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 3278014595
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 12468795292
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 16000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 16000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 21725 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 21697 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 21677 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 21658 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 21631 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 21607 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 21576 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 21561 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 21547 -
|
||||
#10 Vendor (0xff) Completed without error 00% 21530 -
|
||||
#11 Vendor (0xff) Completed without error 00% 21513 -
|
||||
#12 Vendor (0xff) Completed without error 00% 21496 -
|
||||
#13 Vendor (0xff) Completed without error 00% 21479 -
|
||||
#14 Vendor (0xff) Completed without error 00% 21463 -
|
||||
#15 Vendor (0xff) Completed without error 00% 21449 -
|
||||
#16 Vendor (0xff) Completed without error 00% 21435 -
|
||||
#17 Vendor (0xff) Completed without error 00% 21386 -
|
||||
#18 Vendor (0xff) Completed without error 00% 21370 -
|
||||
#19 Vendor (0xff) Completed without error 00% 21356 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/49 Celsius
|
||||
Lifetime Min/Max Temperature: 18/60 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (441)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 229 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 21731 --- Power-on Hours
|
||||
0x01 0x018 6 104879851444 --- Logical Sectors Written
|
||||
0x01 0x020 6 693081810 --- Number of Write Commands
|
||||
0x01 0x028 6 1654419916 --- Logical Sectors Read
|
||||
0x01 0x030 6 20144463 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 228 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 49 --- Current Temperature
|
||||
0x05 0x010 1 48 --- Average Short Term Temperature
|
||||
0x05 0x018 1 43 --- Average Long Term Temperature
|
||||
0x05 0x020 1 60 --- Highest Temperature
|
||||
0x05 0x028 1 18 --- Lowest Temperature
|
||||
0x05 0x030 1 48 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 43 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 43 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1144 --- Number of Hardware Resets
|
||||
0x06 0x010 4 110 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 45 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
214
SSD/Crucial/CT500/CT500MX200SSD1/85009BF49FBA
Normal file
214
SSD/Crucial/CT500/CT500MX200SSD1/85009BF49FBA
Normal file
@@ -0,0 +1,214 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Crucial_CT500MX200SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU03
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 30 09:27:23 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x03) Offline data collection activity
|
||||
is in progress.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 175) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 17846
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1296
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 2369
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 097 097 000 - 60
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 111
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 5557
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 20
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 067 047 000 - 33 (Min/Max 12/53)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 097 097 001 - 3
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 20327817711
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 636038156
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 1372174984
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 16000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 16000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 1224 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 1172 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 1109 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 1035 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 962 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 879 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 798 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 729 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 685 -
|
||||
#10 Vendor (0xff) Completed without error 00% 623 -
|
||||
#11 Vendor (0xff) Completed without error 00% 585 -
|
||||
#12 Vendor (0xff) Completed without error 00% 546 -
|
||||
#13 Vendor (0xff) Completed without error 00% 527 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Completed [00% left] (37722112-37787647)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/44 Celsius
|
||||
Lifetime Min/Max Temperature: 12/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (54)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 2369 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1296 --- Power-on Hours
|
||||
0x01 0x018 6 20327817711 --- Logical Sectors Written
|
||||
0x01 0x020 6 175793607 --- Number of Write Commands
|
||||
0x01 0x028 6 21402151272 --- Logical Sectors Read
|
||||
0x01 0x030 6 343309838 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2352 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 28 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 53 --- Highest Temperature
|
||||
0x05 0x028 1 12 --- Lowest Temperature
|
||||
0x05 0x030 1 35 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 10114 --- Number of Hardware Resets
|
||||
0x06 0x010 4 163 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
210
SSD/Crucial/CT525/CT525MX300SSD1/15A17F9A0137
Normal file
210
SSD/Crucial/CT525/CT525MX300SSD1/15A17F9A0137
Normal file
@@ -0,0 +1,210 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Crucial_CT525MX300SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0CR040
|
||||
User Capacity: 525,112,713,216 bytes [525 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 27 10:35:38 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1391) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 7) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 1154
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 1
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 7215
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1201
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 096 096 000 - 69
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 1035
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 058 041 000 - 42 (Min/Max 9/59)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 2698
|
||||
202 Percent_Lifetime_Remain ----CK 096 096 001 - 4
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 20233612724
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 743866704
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 732104413
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1945
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 9324
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 5870 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 4651 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 3590 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 2604 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 1875 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/42 Celsius
|
||||
Lifetime Min/Max Temperature: 9/59 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (145)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1201 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7215 --- Power-on Hours
|
||||
0x01 0x018 6 20233612724 --- Logical Sectors Written
|
||||
0x01 0x020 6 594712927 --- Number of Write Commands
|
||||
0x01 0x028 6 5983942678 --- Logical Sectors Read
|
||||
0x01 0x030 6 93762374 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1220 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 42 --- Current Temperature
|
||||
0x05 0x010 1 41 --- Average Short Term Temperature
|
||||
0x05 0x018 1 40 --- Average Long Term Temperature
|
||||
0x05 0x020 1 59 --- Highest Temperature
|
||||
0x05 0x028 1 9 --- Lowest Temperature
|
||||
0x05 0x030 1 47 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 37 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 40 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 39 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 7086 --- Number of Hardware Resets
|
||||
0x06 0x010 4 1501 --- Number of ASR Events
|
||||
0x06 0x018 4 2698 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 2 Command failed due to ICRC error
|
||||
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET
|
||||
|
200
SSD/Crucial/FCCT128/FCCT128M4SSD1/17B168CC2ECE
Normal file
200
SSD/Crucial/FCCT128/FCCT128M4SSD1/17B168CC2ECE
Normal file
@@ -0,0 +1,200 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: FCCT128M4SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: 070H
|
||||
User Capacity: 128,035,676,160 bytes [128 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 11:21:43 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 595) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 9) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 19610
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 671
|
||||
170 Unknown_Attribute PO--CK 100 100 010 - 0
|
||||
171 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
173 Unknown_Attribute PO--CK 100 100 010 - 23
|
||||
174 Unknown_Attribute -O--CK 100 100 001 - 73
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 001 - 652840534083
|
||||
183 Runtime_Bad_Block -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 001 - 0
|
||||
188 Command_Timeout -O--CK 100 100 001 - 0
|
||||
189 Unknown_SSD_Attribute -OSR-- 100 100 001 - 102
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 0
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 001 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 001 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 001 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 001 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 001 - 0
|
||||
202 Unknown_SSD_Attribute ---RC- 100 100 001 - 0
|
||||
206 Unknown_SSD_Attribute -OSR-- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 255 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 3449 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log size 3449 not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 0 Celsius
|
||||
Power Cycle Min/Max Temperature: --/ 0 Celsius
|
||||
Lifetime Min/Max Temperature: --/ 0 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (359)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
Write: 40 (4.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 671 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19610 --- Power-on Hours
|
||||
0x01 0x018 6 5122084545 --- Logical Sectors Written
|
||||
0x01 0x020 6 68174321 --- Number of Write Commands
|
||||
0x01 0x028 6 4222252439 --- Logical Sectors Read
|
||||
0x01 0x030 6 97071808 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 0 --- Current Temperature
|
||||
0x05 0x010 1 0 --- Average Short Term Temperature
|
||||
0x05 0x018 1 0 --- Average Long Term Temperature
|
||||
0x05 0x020 1 0 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 0 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 0 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 - --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 47 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 23 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 0 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
207
SSD/Crucial/FCCT128/FCCT128M4SSD1/1AD1B7221CE5
Normal file
207
SSD/Crucial/FCCT128/FCCT128M4SSD1/1AD1B7221CE5
Normal file
@@ -0,0 +1,207 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: FCCT128M4SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: 070H
|
||||
User Capacity: 128,035,676,160 bytes [128 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 11:21:43 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 595) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 9) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 30426
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 8778
|
||||
170 Unknown_Attribute PO--CK 100 100 010 - 0
|
||||
171 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
173 Unknown_Attribute PO--CK 099 099 010 - 48
|
||||
174 Unknown_Attribute -O--CK 100 100 001 - 82
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 001 - 2284954714154
|
||||
183 Runtime_Bad_Block -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 001 - 0
|
||||
188 Command_Timeout -O--CK 100 100 001 - 0
|
||||
189 Unknown_SSD_Attribute -OSR-- 100 100 001 - 96
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 0
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 001 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 001 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 001 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 001 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 001 - 0
|
||||
202 Unknown_SSD_Attribute ---RC- 099 099 001 - 1
|
||||
206 Unknown_SSD_Attribute -OSR-- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 255 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 3449 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log size 3449 not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 2639 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 2608 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 2588 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 2576 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 2563 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 2551 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 2539 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 2526 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 2514 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 0 Celsius
|
||||
Power Cycle Min/Max Temperature: --/ 0 Celsius
|
||||
Lifetime Min/Max Temperature: --/ 0 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (335)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
Write: 40 (4.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 8778 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 30426 --- Power-on Hours
|
||||
0x01 0x018 6 7839642550 --- Logical Sectors Written
|
||||
0x01 0x020 6 106404466 --- Number of Write Commands
|
||||
0x01 0x028 6 6676365431 --- Logical Sectors Read
|
||||
0x01 0x030 6 112986147 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 0 --- Current Temperature
|
||||
0x05 0x010 1 0 --- Average Short Term Temperature
|
||||
0x05 0x018 1 0 --- Average Long Term Temperature
|
||||
0x05 0x020 1 0 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 0 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 0 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 - --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 8 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 0 Device-to-host register FISes sent due to a COMRESET
|
||||
|
201
SSD/Crucial/M4/M4-CT064M4SSD2/AF1883973174
Normal file
201
SSD/Crucial/M4/M4-CT064M4SSD2/AF1883973174
Normal file
@@ -0,0 +1,201 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron RealSSD m4/C400/P400
|
||||
Device Model: M4-CT064M4SSD2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: 040H
|
||||
User Capacity: 64,023,257,088 bytes [64.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 18:20:45 2020 +06
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 295) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 4) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 14143
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 3400
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 001 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
173 Wear_Leveling_Count PO--CK 099 099 010 - 40
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 001 - 28
|
||||
181 Non4k_Aligned_Access -O---K 100 100 001 - 880 184 696
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 001 - 0
|
||||
188 Command_Timeout -O--CK 100 100 001 - 0
|
||||
189 Factory_Bad_Block_Ct -OSR-- 100 100 001 - 51
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 0
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 001 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 001 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 001 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 001 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 001 - 0
|
||||
202 Perc_Rated_Life_Used ---RC- 099 099 001 - 1
|
||||
206 Write_Error_Rate -OSR-- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 255 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 3449 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log size 3449 not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 0 Celsius
|
||||
Power Cycle Min/Max Temperature: --/ 0 Celsius
|
||||
Lifetime Min/Max Temperature: --/ 0 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (56)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
Write: 40 (4.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 3400 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14143 --- Power-on Hours
|
||||
0x01 0x018 6 4383007728 --- Logical Sectors Written
|
||||
0x01 0x020 6 58629997 --- Number of Write Commands
|
||||
0x01 0x028 6 3584721876 --- Logical Sectors Read
|
||||
0x01 0x030 6 75944226 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 0 --- Current Temperature
|
||||
0x05 0x010 1 0 --- Average Short Term Temperature
|
||||
0x05 0x018 1 0 --- Average Long Term Temperature
|
||||
0x05 0x020 1 0 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 0 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 0 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 - --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
51
SSD/Crucial/README.md
Normal file
51
SSD/Crucial/README.md
Normal file
@@ -0,0 +1,51 @@
|
||||
Crucial Solid State Drives
|
||||
==========================
|
||||
|
||||
This is a list of all tested Crucial solid state drive models and their MTBFs. See
|
||||
more info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
Contents
|
||||
--------
|
||||
|
||||
1. [ SSD by Model ](#ssd-by-model)
|
||||
2. [ SSD by Family ](#ssd-by-family)
|
||||
|
||||
SSD by Model
|
||||
------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| Crucial | FCCT128M4SSD1 | 128 GB | 2 | 1042 | 0 | 2.86 |
|
||||
| Crucial | CT240M500SSD3 | 240 GB | 1 | 917 | 0 | 2.51 |
|
||||
| Crucial | CT1050MX300SSD1 | 1 TB | 1 | 811 | 0 | 2.22 |
|
||||
| Crucial | M4-CT064M4SSD2 | 64 GB | 1 | 589 | 0 | 1.61 |
|
||||
| Crucial | CT250MX200SSD1 | 250 GB | 2 | 517 | 0 | 1.42 |
|
||||
| Crucial | CT120BX300SSD1 | 120 GB | 1 | 108 | 0 | 0.30 |
|
||||
| Crucial | CT525MX300SSD1 | 528 GB | 1 | 300 | 2 | 0.27 |
|
||||
| Crucial | CT500MX200SSD1 | 500 GB | 1 | 54 | 0 | 0.15 |
|
||||
| Crucial | CT120BX500SSD1 | 120 GB | 1 | 14 | 0 | 0.04 |
|
||||
|
||||
SSD by Family
|
||||
-------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Family | Models | Samples | Days | Err | MTBF |
|
||||
|-----------|------------------------|--------|---------|-------|-------|--------|
|
||||
| Crucial | Unknown | 1 | 2 | 1042 | 0 | 2.86 |
|
||||
| Crucial | RealSSD m4/C400/P400 | 1 | 1 | 589 | 0 | 1.61 |
|
||||
| Crucial | BX/MX1/2/3/500, M5/... | 7 | 8 | 405 | 1 | 1.04 |
|
Reference in New Issue