1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30
Files
2025-01-05 01:57:11 +03:00

130 lines
6.3 KiB
Plaintext

smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.3 i386] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar 7K250
Device Model: HDS722516VLAT80
Serial Number: --
Firmware Version: V34OA6MA
User Capacity: 164,696,555,520 bytes [164 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-6 T13/1410D revision 3a
Local Time is: Fri May 19 11:17:42 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 3585) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail Always - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
3 Spin_Up_Time 0x0007 105 105 024 Pre-fail Always - 284 (Average 286)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 3878
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 4713
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3777
192 Power-Off_Retract_Count 0x0032 097 097 050 Old_age Always - 3932
193 Load_Cycle_Count 0x0012 097 097 050 Old_age Always - 3932
194 Temperature_Celsius 0x0002 141 141 000 Old_age Always - 39 (Min/Max 15/47)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 2
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 occurred at disk power-on lifetime: 4151 hours (172 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 47 00 5e e0 Error: UNC 8 sectors at LBA = 0x005e0047 = 6160455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 d8 08 47 00 5e e0 00 00:00:20.400 READ DMA EXT
25 d8 08 47 00 5e e0 00 00:00:15.300 READ DMA EXT
25 d8 08 37 00 5e e0 00 00:00:15.300 READ DMA EXT
25 d8 08 2f 00 5e e0 00 00:00:15.300 READ DMA EXT
25 d8 08 2f eb ff e0 00 00:00:15.300 READ DMA EXT
Error 1 occurred at disk power-on lifetime: 4151 hours (172 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 47 00 5e e0 Error: UNC 8 sectors at LBA = 0x005e0047 = 6160455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 d8 08 47 00 5e e0 00 00:00:15.300 READ DMA EXT
25 d8 08 37 00 5e e0 00 00:00:15.300 READ DMA EXT
25 d8 08 2f 00 5e e0 00 00:00:15.300 READ DMA EXT
25 d8 08 2f eb ff e0 00 00:00:15.300 READ DMA EXT
25 d8 08 3f 00 60 e0 00 00:00:15.300 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 4692 -
# 2 Short offline Completed without error 00% 4692 -
# 3 Short offline Completed without error 00% 4691 -
# 4 Short offline Completed without error 00% 2834 -
# 5 Short offline Completed without error 00% 2808 -
# 6 Short offline Completed without error 00% 2793 -
Selective Self-tests/Logging not supported