smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint F3
Device Model: SAMSUNG HD103SJ
Serial Number: --
LU WWN Device Id: 5 0024e9 ...
Firmware Version: 1AJ10001
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sun Nov 5 17:28:50 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 254
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 137) The previous self-test completed having
a test element that failed and the
device is suspected of having handling
damage.
Total time to complete Offline
data collection: ( 9360) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 156) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 001 001 051 NOW 86459
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 070 047 025 - 9196
4 Start_Stop_Count -O--CK 090 090 000 - 11060
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 26071
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 252 252 000 - 0
12 Power_Cycle_Count -O--CK 091 091 000 - 10011
191 G-Sense_Error_Rate -O---K 100 100 000 - 57
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 059 053 000 - 41 (Min/Max 14/47)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 002 002 000 - 8158
198 Offline_Uncorrectable ----CK 081 001 000 - 1611
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 1
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 251
223 Load_Retry_Count -O--CK 252 252 000 - 0
225 Load_Cycle_Count -O--CK 099 099 000 - 11969
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 50001 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 50001 [0] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 05 00 00 00 00 26 0b 40 00 Error: UNC at LBA = 0x0000260b = 9739
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 00 26 08 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 10 00 08 00 00 00 00 26 08 40 00 00:00:00.895 READ FPDMA QUEUED
ef 00 10 00 03 00 00 00 00 00 00 a0 00 00:00:00.895 SET FEATURES [Enable SATA feature]
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:00:00.895 SET FEATURES [Enable write cache]
00 00 00 00 01 00 00 5c 06 60 00 40 00 00:00:00.895 NOP [Abort queued commands]
Error 50000 [7] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 05 00 00 00 00 26 0b 40 00 Error: UNC at LBA = 0x0000260b = 9739
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 00 26 08 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 00 26 08 40 00 00:00:00.865 READ FPDMA QUEUED
60 00 00 00 01 00 00 00 00 08 00 40 00 00:00:00.865 READ FPDMA QUEUED
61 00 00 00 01 00 00 00 00 17 00 40 00 00:00:00.865 WRITE FPDMA QUEUED
61 00 00 00 01 00 00 00 00 08 20 40 00 00:00:00.865 WRITE FPDMA QUEUED
Error 49999 [6] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 07 00 00 00 00 4d 11 40 00 Error: UNC at LBA = 0x00004d11 = 19729
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.841 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.841 READ LOG EXT
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.827 READ FPDMA QUEUED
Error 49998 [5] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 40 00 00 00 00 4d 10 40 00 Error: UNC at LBA = 0x00004d10 = 19728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.827 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.827 READ LOG EXT
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.812 READ FPDMA QUEUED
Error 49997 [4] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 00 4d 10 40 00 Error: UNC at LBA = 0x00004d10 = 19728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.812 READ FPDMA QUEUED
60 00 00 00 01 00 00 00 00 08 00 40 00 00:00:00.812 READ FPDMA QUEUED
61 00 00 00 01 00 00 00 00 17 00 40 00 00:00:00.812 WRITE FPDMA QUEUED
61 00 00 00 01 00 00 00 00 08 20 40 00 00:00:00.812 WRITE FPDMA QUEUED
Error 49996 [3] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 00 39 88 40 00 Error: UNC at LBA = 0x00003988 = 14728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.803 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.803 READ LOG EXT
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.784 READ FPDMA QUEUED
Error 49995 [2] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 40 00 00 00 00 39 88 40 00 Error: UNC at LBA = 0x00003988 = 14728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.784 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.784 READ LOG EXT
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.760 READ FPDMA QUEUED
Error 49994 [1] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
When the command that caused the error occurred, the device was in a vendor specific state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 00 39 88 40 00 Error: UNC at LBA = 0x00003988 = 14728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.760 READ FPDMA QUEUED
61 00 00 00 01 00 00 00 00 17 00 40 00 00:00:00.760 WRITE FPDMA QUEUED
61 00 00 00 01 00 00 00 00 08 20 40 00 00:00:00.760 WRITE FPDMA QUEUED
61 00 00 00 01 00 00 00 00 08 00 40 00 00:00:00.760 WRITE FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: handling damage?? 90% 25616 0
# 2 Short offline Completed: handling damage?? 90% 25610 0
# 3 Short offline Completed: handling damage?? 90% 25605 0
# 4 Short offline Completed: handling damage?? 90% 24229 0
# 5 Extended offline Completed: handling damage?? 90% 24225 0
# 6 Short offline Completed: handling damage?? 90% 24216 0
# 7 Short offline Completed: handling damage?? 90% 24210 0
# 8 Short offline Completed: handling damage?? 90% 19759 0
# 9 Short offline Completed: handling damage?? 90% 19753 0
#10 Short offline Completed: handling damage?? 90% 17294 0
#11 Extended offline Completed: handling damage?? 90% 17294 0
#12 Short offline Completed: handling damage?? 90% 17203 0
#13 Short offline Completed: handling damage?? 90% 11868 0
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed_handling_damage?? [90% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 25/43 Celsius
Lifetime Min/Max Temperature: 17/53 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (54)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 126 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 14 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific