smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: SAMSUNG SpinPoint F3
|
|
Device Model: SAMSUNG HD103SJ
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 0024e9 ...
|
|
Firmware Version: 1AJ10001
|
|
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: 7200 rpm
|
|
Form Factor: 3.5 inches
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
|
SATA Version is: SATA 2.6, 3.0 Gb/s
|
|
Local Time is: Sun Nov 5 17:28:50 2023 UTC
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM level is: 128 (quiet), recommended: 254
|
|
APM feature is: Disabled
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, frozen [SEC2]
|
|
Wt Cache Reorder: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: FAILED!
|
|
Drive failure expected in less than 24 hours. SAVE ALL DATA.
|
|
See vendor-specific Attribute list for failed Attributes.
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x82) Offline data collection activity
|
|
was completed without error.
|
|
Auto Offline Data Collection: Enabled.
|
|
Self-test execution status: ( 137) The previous self-test completed having
|
|
a test element that failed and the
|
|
device is suspected of having handling
|
|
damage.
|
|
Total time to complete Offline
|
|
data collection: ( 9360) seconds.
|
|
Offline data collection
|
|
capabilities: (0x5b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 156) minutes.
|
|
SCT capabilities: (0x003f) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-K 001 001 051 NOW 86459
|
|
2 Throughput_Performance -OS--K 252 252 000 - 0
|
|
3 Spin_Up_Time PO---K 070 047 025 - 9196
|
|
4 Start_Stop_Count -O--CK 090 090 000 - 11060
|
|
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
|
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
|
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
|
9 Power_On_Hours -O--CK 100 100 000 - 26071
|
|
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
|
11 Calibration_Retry_Count -O--CK 252 252 000 - 0
|
|
12 Power_Cycle_Count -O--CK 091 091 000 - 10011
|
|
191 G-Sense_Error_Rate -O---K 100 100 000 - 57
|
|
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
|
194 Temperature_Celsius -O---- 059 053 000 - 41 (Min/Max 14/47)
|
|
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
|
|
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
|
197 Current_Pending_Sector -O--CK 002 002 000 - 8158
|
|
198 Offline_Uncorrectable ----CK 081 001 000 - 1611
|
|
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 1
|
|
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 251
|
|
223 Load_Retry_Count -O--CK 252 252 000 - 0
|
|
225 Load_Cycle_Count -O--CK 099 099 000 - 11969
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 1
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 2 Comprehensive SMART error log
|
|
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 GPL R/O 2 Extended self-test log
|
|
0x08 GPL R/O 2 Power Conditions log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x11 GPL R/O 1 SATA Phy Event Counters log
|
|
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|
0xe0 GPL,SL R/W 1 SCT Command/Status
|
|
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
|
|
|
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
|
Device Error Count: 50001 (device log contains only the most recent 8 errors)
|
|
CR = Command Register
|
|
FEATR = Features Register
|
|
COUNT = Count (was: Sector Count) Register
|
|
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
|
LH = LBA High (was: Cylinder High) Register ] LBA
|
|
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
|
LL = LBA Low (was: Sector Number) Register ]
|
|
DV = Device (was: Device/Head) Register
|
|
DC = Device Control Register
|
|
ER = Error register
|
|
ST = Status register
|
|
Powered_Up_Time is measured from power on, and printed as
|
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|
|
|
Error 50001 [0] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 05 00 00 00 00 26 0b 40 00 Error: UNC at LBA = 0x0000260b = 9739
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 08 00 00 00 00 26 08 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 10 00 08 00 00 00 00 26 08 40 00 00:00:00.895 READ FPDMA QUEUED
|
|
ef 00 10 00 03 00 00 00 00 00 00 a0 00 00:00:00.895 SET FEATURES [Enable SATA feature]
|
|
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:00:00.895 SET FEATURES [Enable write cache]
|
|
00 00 00 00 01 00 00 5c 06 60 00 40 00 00:00:00.895 NOP [Abort queued commands]
|
|
|
|
Error 50000 [7] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 05 00 00 00 00 26 0b 40 00 Error: UNC at LBA = 0x0000260b = 9739
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 08 00 00 00 00 26 08 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 08 00 00 00 00 26 08 40 00 00:00:00.865 READ FPDMA QUEUED
|
|
60 00 00 00 01 00 00 00 00 08 00 40 00 00:00:00.865 READ FPDMA QUEUED
|
|
61 00 00 00 01 00 00 00 00 17 00 40 00 00:00:00.865 WRITE FPDMA QUEUED
|
|
61 00 00 00 01 00 00 00 00 08 20 40 00 00:00:00.865 WRITE FPDMA QUEUED
|
|
|
|
Error 49999 [6] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 07 00 00 00 00 4d 11 40 00 Error: UNC at LBA = 0x00004d11 = 19729
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.841 READ FPDMA QUEUED
|
|
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.841 READ LOG EXT
|
|
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.827 READ FPDMA QUEUED
|
|
|
|
Error 49998 [5] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 40 00 00 00 00 4d 10 40 00 Error: UNC at LBA = 0x00004d10 = 19728
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 40 00 00 00 00 4d 10 40 00 00:00:00.827 READ FPDMA QUEUED
|
|
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.827 READ LOG EXT
|
|
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.812 READ FPDMA QUEUED
|
|
|
|
Error 49997 [4] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 08 00 00 00 00 4d 10 40 00 Error: UNC at LBA = 0x00004d10 = 19728
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 08 00 00 00 00 4d 10 40 00 00:00:00.812 READ FPDMA QUEUED
|
|
60 00 00 00 01 00 00 00 00 08 00 40 00 00:00:00.812 READ FPDMA QUEUED
|
|
61 00 00 00 01 00 00 00 00 17 00 40 00 00:00:00.812 WRITE FPDMA QUEUED
|
|
61 00 00 00 01 00 00 00 00 08 20 40 00 00:00:00.812 WRITE FPDMA QUEUED
|
|
|
|
Error 49996 [3] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 08 00 00 00 00 39 88 40 00 Error: UNC at LBA = 0x00003988 = 14728
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.803 READ FPDMA QUEUED
|
|
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.803 READ LOG EXT
|
|
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.784 READ FPDMA QUEUED
|
|
|
|
Error 49995 [2] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 40 00 00 00 00 39 88 40 00 Error: UNC at LBA = 0x00003988 = 14728
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 40 00 00 00 00 39 88 40 00 00:00:00.784 READ FPDMA QUEUED
|
|
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.784 READ LOG EXT
|
|
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.760 READ FPDMA QUEUED
|
|
|
|
Error 49994 [1] occurred at disk power-on lifetime: 25979 hours (1082 days + 11 hours)
|
|
When the command that caused the error occurred, the device was in a vendor specific state.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 08 00 00 00 00 39 88 40 00 Error: UNC at LBA = 0x00003988 = 14728
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.570 READ FPDMA QUEUED
|
|
60 00 00 00 08 00 00 00 00 39 88 40 00 00:00:00.760 READ FPDMA QUEUED
|
|
61 00 00 00 01 00 00 00 00 17 00 40 00 00:00:00.760 WRITE FPDMA QUEUED
|
|
61 00 00 00 01 00 00 00 00 08 20 40 00 00:00:00.760 WRITE FPDMA QUEUED
|
|
61 00 00 00 01 00 00 00 00 08 00 40 00 00:00:00.760 WRITE FPDMA QUEUED
|
|
|
|
SMART Extended Self-test Log Version: 1 (2 sectors)
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Short offline Completed: handling damage?? 90% 25616 0
|
|
# 2 Short offline Completed: handling damage?? 90% 25610 0
|
|
# 3 Short offline Completed: handling damage?? 90% 25605 0
|
|
# 4 Short offline Completed: handling damage?? 90% 24229 0
|
|
# 5 Extended offline Completed: handling damage?? 90% 24225 0
|
|
# 6 Short offline Completed: handling damage?? 90% 24216 0
|
|
# 7 Short offline Completed: handling damage?? 90% 24210 0
|
|
# 8 Short offline Completed: handling damage?? 90% 19759 0
|
|
# 9 Short offline Completed: handling damage?? 90% 19753 0
|
|
#10 Short offline Completed: handling damage?? 90% 17294 0
|
|
#11 Extended offline Completed: handling damage?? 90% 17294 0
|
|
#12 Short offline Completed: handling damage?? 90% 17203 0
|
|
#13 Short offline Completed: handling damage?? 90% 11868 0
|
|
|
|
SMART Selective self-test log data structure revision number 0
|
|
Note: revision number not 1 implies that no selective self-test has ever been run
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Completed_handling_damage?? [90% left] (0-65535)
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Status Version: 2
|
|
SCT Version (vendor specific): 256 (0x0100)
|
|
Device State: Active (0)
|
|
Current Temperature: 41 Celsius
|
|
Power Cycle Min/Max Temperature: 25/43 Celsius
|
|
Lifetime Min/Max Temperature: 17/53 Celsius
|
|
Specified Max Operating Temperature: 80 Celsius
|
|
Under/Over Temperature Limit Count: 0/0
|
|
|
|
SCT Temperature History Version: 2
|
|
Temperature Sampling Period: 5 minutes
|
|
Temperature Logging Interval: 5 minutes
|
|
Min/Max recommended Temperature: -5/80 Celsius
|
|
Min/Max Temperature Limit: -10/85 Celsius
|
|
Temperature History Size (Index): 128 (54)
|
|
|
|
SCT Error Recovery Control:
|
|
Read: Disabled
|
|
Write: Disabled
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11)
|
|
ID Size Value Description
|
|
0x0001 4 0 Command failed due to ICRC error
|
|
0x0002 4 0 R_ERR response for data FIS
|
|
0x0003 4 0 R_ERR response for device-to-host data FIS
|
|
0x0004 4 0 R_ERR response for host-to-device data FIS
|
|
0x0005 4 0 R_ERR response for non-data FIS
|
|
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
|
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
|
0x0008 4 0 Device-to-host non-data FIS retries
|
|
0x0009 4 126 Transition from drive PhyRdy to drive PhyNRdy
|
|
0x000a 4 14 Device-to-host register FISes sent due to a COMRESET
|
|
0x000b 4 0 CRC errors within host-to-device FIS
|
|
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
|
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
|
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
|
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
|
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
|
0x8e00 4 0 Vendor specific
|
|
0x8e01 4 0 Vendor specific
|
|
0x8e02 4 0 Vendor specific
|
|
0x8e03 4 0 Vendor specific
|
|
0x8e04 4 0 Vendor specific
|
|
0x8e05 4 0 Vendor specific
|
|
0x8e06 4 0 Vendor specific
|
|
0x8e07 4 0 Vendor specific
|
|
0x8e08 4 0 Vendor specific
|
|
0x8e09 4 0 Vendor specific
|
|
0x8e0a 4 0 Vendor specific
|
|
0x8e0b 4 0 Vendor specific
|
|
0x8e0c 4 0 Vendor specific
|
|
0x8e0d 4 0 Vendor specific
|
|
0x8e0e 4 0 Vendor specific
|
|
0x8e0f 4 0 Vendor specific
|
|
0x8e10 4 0 Vendor specific
|
|
0x8e11 4 0 Vendor specific
|
|
|
|
|
|
|