smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
|
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: SAMSUNG SpinPoint M40/60/80
|
|
Device Model: SAMSUNG HM080HI
|
|
Serial Number: --
|
|
Firmware Version: AB100-12
|
|
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Device is: In smartctl database [for details use: -P show]
|
|
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
|
|
Local Time is: Tue Aug 11 21:39:39 2020 +05
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Disabled
|
|
APM level is: 254 (maximum performance)
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, frozen [SEC2]
|
|
Wt Cache Reorder: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
See vendor-specific Attribute list for marginal Attributes.
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x82) Offline data collection activity
|
|
was completed without error.
|
|
Auto Offline Data Collection: Enabled.
|
|
Self-test execution status: ( 121) The previous self-test completed having
|
|
the read element of the test failed.
|
|
Total time to complete Offline
|
|
data collection: ( 2670) seconds.
|
|
Offline data collection
|
|
capabilities: (0x5b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 44) minutes.
|
|
SCT capabilities: (0x003f) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-- 253 100 051 - 0
|
|
3 Spin_Up_Time POS--- 253 253 025 - 2304
|
|
4 Start_Stop_Count -O--CK 070 070 000 - 30953
|
|
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 1
|
|
7 Seek_Error_Rate -OSR-- 253 253 000 - 0
|
|
8 Seek_Time_Performance --S--K 253 253 000 - 0
|
|
9 Power_On_Half_Minutes -O--CK 098 098 000 - 15054h+41m
|
|
10 Spin_Retry_Count -O--CK 100 100 000 - 30
|
|
11 Calibration_Retry_Count -O--C- 100 100 000 - 4
|
|
12 Power_Cycle_Count -O--CK 095 095 000 - 5052
|
|
187 Reported_Uncorrect -O--CK 077 077 000 - 24
|
|
188 Command_Timeout -O--CK 253 253 000 - 0
|
|
190 Airflow_Temperature_Cel -O---K 054 038 040 Past 46 (Min/Max 13/62)
|
|
191 G-Sense_Error_Rate -O--C- 089 089 000 - 116567
|
|
192 Power-Off_Retract_Count -O--C- 100 100 000 - 918
|
|
193 Load_Cycle_Count -O--C- 054 054 000 - 466783
|
|
194 Temperature_Celsius -O---K 054 038 000 - 46 (Min/Max 13/62)
|
|
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 29070
|
|
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
|
|
197 Current_Pending_Sector -O--C- 253 100 000 - 0
|
|
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
|
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
|
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
|
201 Soft_Read_Error_Rate -O--C- 253 253 000 - 0
|
|
223 Load_Retry_Count -O--C- 100 100 000 - 4
|
|
225 Load_Cycle_Count -O--C- 054 054 000 - 466783
|
|
255 Unknown_Attribute -O-R-- 253 100 000 - 0
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 1
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 2 Comprehensive SMART error log
|
|
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 GPL R/O 1 Extended self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x11 GPL R/O 1 SATA Phy Event Counters log
|
|
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|
|
|
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
|
Invalid Error Log index = 0x0600 (reserved = 0x00)
|
|
SMART Extended Self-test Log Version: 1 (1 sectors)
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Short offline Completed: read failure 90% 13047 147068954
|
|
# 2 Short offline Completed without error 00% 12261 -
|
|
# 3 Short offline Interrupted (host reset) 80% 10708 -
|
|
# 4 Short offline Completed without error 00% 5551 -
|
|
# 5 Short offline Completed without error 00% 3134 -
|
|
# 6 Short offline Completed without error 00% 2421 -
|
|
# 7 Short offline Completed without error 00% 0 -
|
|
|
|
SMART Selective self-test log data structure revision number 0
|
|
Note: revision number not 1 implies that no selective self-test has ever been run
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Status Version: 2
|
|
SCT Version (vendor specific): 256 (0x0100)
|
|
Device State: Active (0)
|
|
Current Temperature: 46 Celsius
|
|
Power Cycle Min/Max Temperature: --/46 Celsius
|
|
Lifetime Min/Max Temperature: --/62 Celsius
|
|
|
|
Unknown SCT Status format version 0, should be 2 or 3.
|
|
Read SCT Temperature History failed
|
|
|
|
Read SCT Status failed: Input/output error
|
|
SCT (Get) Error Recovery Control command failed
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: Input/output error
|
|
Read SATA Phy Event Counters failed
|
|
|