mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
108 lines
5.4 KiB
Plaintext
108 lines
5.4 KiB
Plaintext
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: SAMSUNG SpinPoint M7E (AF)
|
|
Device Model: SAMSUNG HM321HI
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 0024e9 ...
|
|
Firmware Version: 2AJ10001
|
|
User Capacity: 320,072,933,376 bytes [320 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: 5400 rpm
|
|
Form Factor: 2.5 inches
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
|
SATA Version is: SATA 2.6, 3.0 Gb/s
|
|
Local Time is: Thu Mar 24 17:43:41 2022 CET
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART Status not supported: Incomplete response, ATA output registers missing
|
|
SMART overall-health self-assessment test result: PASSED
|
|
Warning: This result is based on an Attribute check.
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 24) The self-test routine was aborted by
|
|
the host.
|
|
Total time to complete Offline
|
|
data collection: ( 4800) seconds.
|
|
Offline data collection
|
|
capabilities: (0x5b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 80) minutes.
|
|
SCT capabilities: (0x003f) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
|
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 19
|
|
2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
|
|
3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3407
|
|
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 852
|
|
5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
|
|
7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
|
|
8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
|
|
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 327
|
|
10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
|
|
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 721
|
|
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 825
|
|
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 974
|
|
192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
|
|
194 Temperature_Celsius 0x0002 064 064 000 Old_age Always - 28 (Min/Max 12/38)
|
|
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
|
|
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
|
|
197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0
|
|
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
|
|
199 UDMA_CRC_Error_Count 0x0036 100 100 000 Old_age Always - 11
|
|
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 42
|
|
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 721
|
|
225 Load_Cycle_Count 0x0032 098 098 000 Old_age Always - 21035
|
|
|
|
SMART Error Log Version: 1
|
|
No Errors Logged
|
|
|
|
SMART Self-test log structure revision number 1
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Short offline Aborted by host 80% 180 -
|
|
# 2 Extended offline Aborted by host 90% 0 -
|
|
# 3 Short offline Completed without error 00% 0 -
|
|
# 4 Extended offline Aborted by host 90% 0 -
|
|
# 5 Short offline Aborted by host 80% 0 -
|
|
|
|
SMART Selective self-test log data structure revision number 0
|
|
Note: revision number not 1 implies that no selective self-test has ever been run
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Aborted_by_host [80% left] (0-65535)
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
|
|
|