smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate U10
Device Model: ST310212A
Serial Number: --
Firmware Version: 3.02
User Capacity: 10,242,892,800 bytes [10.2 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-5 (minor revision not indicated)
Local Time is: Wed Feb 22 18:14:44 2023 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 64 (intermediate level with standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Unavailable
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2400) seconds.
Offline data collection
capabilities: (0x1d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 14) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate ---R-- 082 082 000 - 231736924
3 Spin_Up_Time -OS--- 098 098 000 - 0
4 Start_Stop_Count PO--C- 100 100 020 - 685
5 Reallocated_Sector_Ct PO--C- 100 100 036 - 24
7 Seek_Error_Rate P--R-- 068 060 030 - 38711262534
9 Power_On_Hours -O--C- 084 084 000 - 14648
10 Spin_Retry_Count PO--C- 100 099 090 - 0
12 Power_Cycle_Count PO--C- 098 098 000 - 2128
197 Current_Pending_Sector ----CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 38 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 38 occurred at disk power-on lifetime: 493 hours (20 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 7c 93 c3 28 e1 Error: UNC at LBA = 0x0128c393 = 19448723
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 70 9f c3 28 e1 00 00:11:44.148 READ VERIFY SECTOR(S)
40 00 50 bf c3 28 e1 00 00:11:26.052 READ VERIFY SECTOR(S)
40 00 d0 3f c2 28 e1 00 00:11:18.761 READ VERIFY SECTOR(S)
40 00 d0 3f c1 28 e1 00 00:11:18.754 READ VERIFY SECTOR(S)
40 00 d0 3f c0 28 e1 00 00:11:18.744 READ VERIFY SECTOR(S)
Error 37 occurred at disk power-on lifetime: 493 hours (20 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 7c 93 c3 28 e1 Error: UNC at LBA = 0x0128c393 = 19448723
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 70 9f c3 28 e1 00 00:11:44.148 READ VERIFY SECTOR(S)
40 00 50 bf c3 28 e1 00 00:11:26.052 READ VERIFY SECTOR(S)
40 00 d0 3f c2 28 e1 00 00:11:18.761 READ VERIFY SECTOR(S)
40 00 d0 3f c1 28 e1 00 00:11:18.754 READ VERIFY SECTOR(S)
40 00 d0 3f c0 28 e1 00 00:11:18.744 READ VERIFY SECTOR(S)
Error 36 occurred at disk power-on lifetime: 493 hours (20 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 7c 93 c3 28 e1 Error: UNC at LBA = 0x0128c393 = 19448723
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 70 9f c3 28 e1 00 00:11:44.148 READ VERIFY SECTOR(S)
40 00 50 bf c3 28 e1 00 00:11:26.052 READ VERIFY SECTOR(S)
40 00 d0 3f c2 28 e1 00 00:11:18.761 READ VERIFY SECTOR(S)
40 00 d0 3f c1 28 e1 00 00:11:18.754 READ VERIFY SECTOR(S)
40 00 d0 3f c0 28 e1 00 00:11:18.744 READ VERIFY SECTOR(S)
Error 35 occurred at disk power-on lifetime: 493 hours (20 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 7c 93 c3 28 e1 Error: UNC at LBA = 0x0128c393 = 19448723
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 70 9f c3 28 e1 00 00:11:44.148 READ VERIFY SECTOR(S)
40 00 50 bf c3 28 e1 00 00:11:26.052 READ VERIFY SECTOR(S)
40 00 d0 3f c2 28 e1 00 00:11:18.761 READ VERIFY SECTOR(S)
40 00 d0 3f c1 28 e1 00 00:11:18.754 READ VERIFY SECTOR(S)
40 00 d0 3f c0 28 e1 00 00:11:18.744 READ VERIFY SECTOR(S)
Error 34 occurred at disk power-on lifetime: 493 hours (20 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 7c 93 c3 28 e1 Error: UNC at LBA = 0x0128c393 = 19448723
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 70 9f c3 28 e1 00 00:11:44.148 READ VERIFY SECTOR(S)
40 00 50 bf c3 28 e1 00 00:11:26.052 READ VERIFY SECTOR(S)
40 00 d0 3f c2 28 e1 00 00:11:18.761 READ VERIFY SECTOR(S)
40 00 d0 3f c1 28 e1 00 00:11:18.754 READ VERIFY SECTOR(S)
40 00 d0 3f c0 28 e1 00 00:11:18.744 READ VERIFY SECTOR(S)
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported