smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p4 amd64] (local build)
|
|
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
|
|
Device Model: ST3120026AS
|
|
Serial Number: --
|
|
Firmware Version: 3.18
|
|
User Capacity: 120,034,123,776 bytes [120 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Device is: In smartctl database 7.3/5528
|
|
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
|
|
Local Time is: Thu Sep 26 12:07:46 2024 MSK
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM feature is: Unavailable
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
|
Wt Cache Reorder: Unavailable
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x82) Offline data collection activity
|
|
was completed without error.
|
|
Auto Offline Data Collection: Enabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 430) seconds.
|
|
Offline data collection
|
|
capabilities: (0x5b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
No General Purpose Logging support.
|
|
Short self-test routine
|
|
recommended polling time: ( 1) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 85) minutes.
|
|
|
|
SMART Attributes Data Structure revision number: 10
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-- 068 050 006 - 241218222
|
|
3 Spin_Up_Time PO---- 097 096 000 - 0
|
|
4 Start_Stop_Count -O--CK 100 100 020 - 2
|
|
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 28
|
|
7 Seek_Error_Rate POSR-- 084 060 030 - 4586828452
|
|
9 Power_On_Hours -O--CK 075 075 000 - 22252
|
|
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
|
12 Power_Cycle_Count -O--CK 100 100 020 - 247
|
|
194 Temperature_Celsius -O---K 041 054 000 - 41
|
|
195 Hardware_ECC_Recovered -O-RC- 068 050 000 - 241218222
|
|
197 Current_Pending_Sector -O--C- 100 100 000 - 43
|
|
198 Offline_Uncorrectable ----C- 100 100 000 - 43
|
|
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
|
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
|
202 Data_Address_Mark_Errs -O--CK 098 251 000 - 2
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory not supported
|
|
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 5 Comprehensive SMART error log
|
|
0x03 SL R/O 5 Ext. Comprehensive SMART error log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 SL R/O 1 Extended self-test log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x20 SL R/O 1 Streaming performance log
|
|
0x21 SL R/O 1 Write stream error log
|
|
0x22 SL R/O 1 Read stream error log
|
|
0x23 SL R/O 1 Delayed sector log
|
|
0x80-0x9f SL R/W 16 Host vendor specific log
|
|
0xa0 SL VS 1 Device vendor specific log
|
|
0xa1 SL VS 20 Device vendor specific log
|
|
0xa2 SL VS 101 Device vendor specific log
|
|
0xa8 SL VS 20 Device vendor specific log
|
|
0xa9 SL VS 1 Device vendor specific log
|
|
|
|
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
|
|
|
SMART Error Log Version: 1
|
|
ATA Error Count: 669 (device log contains only the most recent five errors)
|
|
CR = Command Register [HEX]
|
|
FR = Features Register [HEX]
|
|
SC = Sector Count Register [HEX]
|
|
SN = Sector Number Register [HEX]
|
|
CL = Cylinder Low Register [HEX]
|
|
CH = Cylinder High Register [HEX]
|
|
DH = Device/Head Register [HEX]
|
|
DC = Device Command Register [HEX]
|
|
ER = Error register [HEX]
|
|
ST = Status register [HEX]
|
|
Powered_Up_Time is measured from power on, and printed as
|
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|
|
|
Error 669 occurred at disk power-on lifetime: 22005 hours (916 days + 21 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 a4 04 0c 40 Error: UNC at LBA = 0x000c04a4 = 787620
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 03 01 a4 04 0c 40 00 17:22:56.787 READ DMA
|
|
c8 03 01 a3 04 0c 40 00 17:23:30.168 READ DMA
|
|
c8 03 01 a2 04 0c 40 00 17:23:30.167 READ DMA
|
|
ef 03 46 01 00 00 00 00 17:23:30.154 SET FEATURES [Set transfer mode]
|
|
ec 00 01 01 00 00 00 00 17:23:30.143 IDENTIFY DEVICE
|
|
|
|
Error 668 occurred at disk power-on lifetime: 22004 hours (916 days + 20 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 a1 04 0c 40 Error: UNC at LBA = 0x000c04a1 = 787617
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 03 01 a1 04 0c 40 00 17:21:53.866 READ DMA
|
|
c8 03 01 a0 04 0c 40 00 17:21:53.866 READ DMA
|
|
c8 03 01 9f 04 0c 40 00 17:21:53.866 READ DMA
|
|
c8 03 01 9e 04 0c 40 00 17:21:53.866 READ DMA
|
|
c8 03 01 9d 04 0c 40 00 17:21:53.866 READ DMA
|
|
|
|
Error 667 occurred at disk power-on lifetime: 22004 hours (916 days + 20 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 21 a1 04 0c 40 Error: UNC 33 sectors at LBA = 0x000c04a1 = 787617
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 03 40 80 04 0c 40 00 17:20:14.385 READ DMA
|
|
c8 03 40 c0 50 07 40 00 17:20:14.332 READ DMA
|
|
c8 03 40 40 41 07 40 00 17:20:14.330 READ DMA
|
|
c8 03 40 c0 1e 30 40 00 17:20:14.315 READ DMA
|
|
c8 03 40 c0 ec 10 40 00 17:20:14.314 READ DMA
|
|
|
|
Error 666 occurred at disk power-on lifetime: 22004 hours (916 days + 20 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 cd ff 02 40 Error: UNC at LBA = 0x0002ffcd = 196557
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 03 01 cd ff 02 40 00 17:13:01.967 READ DMA
|
|
ef 03 46 01 00 00 00 00 17:13:01.738 SET FEATURES [Set transfer mode]
|
|
ec 00 01 01 00 00 00 00 17:13:01.225 IDENTIFY DEVICE
|
|
00 00 01 00 00 00 00 ff 17:13:00.996 NOP [Abort queued commands]
|
|
00 00 01 00 00 00 00 ff 17:12:30.483 NOP [Abort queued commands]
|
|
|
|
Error 665 occurred at disk power-on lifetime: 22004 hours (916 days + 20 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 cc ff 02 40 Error: UNC at LBA = 0x0002ffcc = 196556
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 03 01 cc ff 02 40 00 17:10:53.990 READ DMA
|
|
c8 03 01 cb ff 02 40 00 17:10:53.761 READ DMA
|
|
ef 03 46 01 00 00 00 00 17:10:53.247 SET FEATURES [Set transfer mode]
|
|
ec 00 01 01 00 00 00 00 17:10:53.019 IDENTIFY DEVICE
|
|
00 00 46 00 00 00 00 ff 17:11:26.300 NOP [Abort queued commands]
|
|
|
|
SMART Extended Self-test Log (GP Log 0x07) not supported
|
|
|
|
SMART Self-test log structure revision number 1
|
|
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Commands not supported
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11) not supported
|
|
|