smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-STABLE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.9
Device Model: ST3120814A
Serial Number: --
Firmware Version: 2AAA
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Mon Aug 30 12:22:27 2021 +07
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 51) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 046 030 006 - 27876967
3 Spin_Up_Time PO---- 099 099 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 909
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 12
7 Seek_Error_Rate POSR-- 086 060 030 - 415881013
9 Power_On_Hours -O--CK 001 001 000 - 95393
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 934
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 096 096 000 - 4
190 Airflow_Temperature_Cel -O---K 056 047 045 - 44 (Min/Max 27/49)
194 Temperature_Celsius -O---K 044 053 000 - 44 (0 12 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 054 043 000 - 190404035
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 199 000 - 1
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23552 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 19
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 19 [18] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:56.987 READ DMA
c6 00 00 00 10 00 00 00 00 00 00 e0 00 00:07:56.512 SET MULTIPLE MODE
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 00:07:56.512 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 00 01 00 00 00 00 00 00 00 e0 00 00:07:56.512 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:07:56.511 NOP [Abort queued commands]
Error 18 [17] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:44.234 READ DMA
c6 00 00 00 10 00 00 00 00 00 00 e0 00 00:07:56.512 SET MULTIPLE MODE
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 00:07:56.512 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 00 01 00 00 00 00 00 00 00 e0 00 00:07:56.512 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:07:56.511 NOP [Abort queued commands]
Error 17 [16] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:44.234 READ DMA
b0 00 d9 00 10 00 02 17 00 fd 10 a0 00 00:07:42.412 SMART DISABLE OPERATIONS
b0 00 da 00 10 00 02 17 00 fd 10 a0 00 00:00:07.947 SMART RETURN STATUS
b0 00 d8 00 10 00 02 17 00 fd 10 a0 00 00:00:04.590 SMART ENABLE OPERATIONS
c6 00 03 00 10 00 00 00 00 00 00 a0 00 1d+13:16:57.727 SET MULTIPLE MODE
Error 16 [15] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:56.987 READ DMA
c6 00 00 00 10 00 00 00 00 00 00 e0 00 00:07:56.512 SET MULTIPLE MODE
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 00:07:56.512 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 00 01 00 00 00 00 00 00 00 e0 00 00:07:56.512 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:07:56.511 NOP [Abort queued commands]
Error 15 [14] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:56.987 READ DMA
c6 00 00 00 10 00 00 00 00 00 00 e0 00 00:07:56.512 SET MULTIPLE MODE
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 00:07:56.512 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 00 01 00 00 00 00 00 00 00 e0 00 00:07:56.512 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:07:56.511 NOP [Abort queued commands]
Error 14 [13] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:44.234 READ DMA
c6 00 00 00 10 00 00 00 00 00 00 e0 00 00:07:56.512 SET MULTIPLE MODE
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 00:07:56.512 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 00 01 00 00 00 00 00 00 00 e0 00 00:07:56.512 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:07:56.511 NOP [Abort queued commands]
Error 13 [12] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:44.234 READ DMA
b0 00 d9 00 10 00 02 17 00 fd 10 a0 00 00:07:42.412 SMART DISABLE OPERATIONS
b0 00 da 00 10 00 02 17 00 fd 10 a0 00 00:00:07.947 SMART RETURN STATUS
b0 00 d8 00 10 00 02 17 00 fd 10 a0 00 00:00:04.590 SMART ENABLE OPERATIONS
c6 00 03 00 10 00 00 00 00 00 00 a0 00 1d+13:16:57.727 SET MULTIPLE MODE
Error 12 [11] occurred at disk power-on lifetime: 14146 hours (589 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 00 00 00 00 00 00 00 e0 00 Error: ICRC, ABRT 256 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:07:56.987 READ DMA
c6 00 00 00 10 00 00 00 00 00 00 e0 00 00:07:56.512 SET MULTIPLE MODE
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 00:07:56.512 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 00 01 00 00 00 00 00 00 00 e0 00 00:07:56.512 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:07:56.511 NOP [Abort queued commands]
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 5453 -
# 2 Short offline Completed without error 00% 5453 -
# 3 Extended offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported