smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Toshiba P300
Device Model: TOSHIBA HDWD110
Serial Number: --
LU WWN Device Id: 5 000039 ...
Firmware Version: MS2OA8R0
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 1 22:03:35 2021 -05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 6973) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 117) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 142 142 054 - 68
3 Spin_Up_Time POS--- 117 117 024 - 190 (Average 201)
4 Start_Stop_Count -O--C- 100 100 000 - 1313
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 115 115 020 - 34
9 Power_On_Hours -O--C- 100 100 000 - 2184
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1312
192 Power-Off_Retract_Count -O--CK 099 099 000 - 1502
193 Load_Cycle_Count -O--C- 099 099 000 - 1502
194 Temperature_Celsius -O---- 153 153 000 - 39 (Min/Max 23/46)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 6
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 7 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
Device Error Count: 6 (device log contains only the most recent 4 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 6 [1] occurred at disk power-on lifetime: 122 hours (5 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 50 07 1f 00 00 Error: ICRC, ABRT at LBA = 0x0050071f = 5244703
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 a0 00 00 00 50 07 18 40 00 00:08:32.583 READ FPDMA QUEUED
60 00 08 00 98 00 00 00 50 07 10 40 00 00:08:32.583 READ FPDMA QUEUED
60 00 08 00 90 00 00 00 50 07 08 40 00 00:08:32.583 READ FPDMA QUEUED
60 00 08 00 88 00 00 00 50 07 00 40 00 00:08:32.583 READ FPDMA QUEUED
60 00 08 00 80 00 00 00 50 06 f0 40 00 00:08:32.582 READ FPDMA QUEUED
Error 5 [0] occurred at disk power-on lifetime: 122 hours (5 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 50 06 ef 00 00 Error: ICRC, ABRT at LBA = 0x005006ef = 5244655
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 78 00 00 00 50 06 e8 40 00 00:08:32.210 READ FPDMA QUEUED
60 00 08 00 70 00 00 00 50 06 e0 40 00 00:08:32.210 READ FPDMA QUEUED
60 00 08 00 68 00 00 00 50 06 d8 40 00 00:08:32.210 READ FPDMA QUEUED
60 00 08 00 60 00 00 00 50 06 d0 40 00 00:08:32.210 READ FPDMA QUEUED
60 00 08 00 58 00 00 00 50 06 c8 40 00 00:08:32.210 READ FPDMA QUEUED
Error 4 [3] occurred at disk power-on lifetime: 122 hours (5 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 d9 00 00 00 50 06 1f 00 00 Error: ICRC, ABRT at LBA = 0x0050061f = 5244447
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 68 00 58 00 00 00 50 07 88 40 00 00:08:31.827 READ FPDMA QUEUED
60 00 80 00 50 00 00 00 50 07 00 40 00 00:08:31.827 READ FPDMA QUEUED
60 00 f8 00 48 00 00 00 50 06 00 40 00 00:08:31.827 READ FPDMA QUEUED
60 02 00 00 40 00 00 00 50 04 00 40 00 00:08:31.808 READ FPDMA QUEUED
60 00 f8 00 90 00 00 00 50 09 08 40 00 00:08:31.808 READ FPDMA QUEUED
Error 3 [2] occurred at disk power-on lifetime: 122 hours (5 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 08 3f 00 00 Error: ICRC, ABRT at LBA = 0x0000083f = 2111
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 08 00 00 00 00 08 38 40 00 00:08:31.372 READ FPDMA QUEUED
60 00 08 00 38 00 00 00 10 09 00 40 00 00:08:31.372 READ FPDMA QUEUED
60 00 08 00 00 00 00 00 00 08 18 40 00 00:08:31.368 READ FPDMA QUEUED
60 00 08 00 48 00 00 00 90 18 00 40 00 00:08:31.368 READ FPDMA QUEUED
60 00 08 00 f0 00 00 00 00 08 28 40 00 00:08:31.368 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 38/41 Celsius
Lifetime Min/Max Temperature: 23/46 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (64)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1312 --- Lifetime Power-On Resets
0x01 0x010 4 2184 --- Power-on Hours
0x01 0x018 6 8759890747 --- Logical Sectors Written
0x01 0x020 6 122894072 --- Number of Write Commands
0x01 0x028 6 72063072107 --- Logical Sectors Read
0x01 0x030 6 78366669 --- Number of Read Commands
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 2137 --- Spindle Motor Power-on Hours
0x03 0x010 4 2137 --- Head Flying Hours
0x03 0x018 4 1502 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 3 --- Read Recovery Attempts
0x03 0x030 4 9 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 5 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 39 --- Current Temperature
0x05 0x010 1 39 N-- Average Short Term Temperature
0x05 0x018 1 38 N-- Average Long Term Temperature
0x05 0x020 1 46 --- Highest Temperature
0x05 0x028 1 23 --- Lowest Temperature
0x05 0x030 1 40 N-- Highest Average Short Term Temperature
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
0x05 0x040 1 38 N-- Highest Average Long Term Temperature
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 3103 --- Number of Hardware Resets
0x06 0x010 4 1863 --- Number of ASR Events
0x06 0x018 4 6 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS