smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Toshiba 2.5" HDD (30-60 GB)
Device Model: TOSHIBA MK6034GSX
Serial Number: --
Firmware Version: AH101A
User Capacity: 60,011,642,880 bytes [60.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Fri Jul 15 19:40:12 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 219) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 43) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Spin_Up_Time POS--K 100 100 001 - 1048
4 Start_Stop_Count -O--CK 100 100 000 - 5090
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
8 Seek_Time_Performance P-S--- 100 100 050 - 0
9 Power_On_Hours -O--CK 076 076 000 - 9930
10 Spin_Retry_Count PO--CK 201 100 030 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 4987
192 Power-Off_Retract_Count -O--CK 100 100 000 - 210
193 Load_Cycle_Count -O--CK 076 076 000 - 249071
194 Temperature_Celsius -O---K 100 100 000 - 26 (Min/Max 15/51)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 1
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 4
220 Disk_Shift -O---- 100 100 000 - 4214
222 Loaded_Hours -O--CK 086 086 000 - 5926
223 Load_Retry_Count -O--CK 100 100 000 - 0
224 Load_Friction -O---K 100 100 000 - 0
226 Load-in_Time -OS--K 100 100 000 - 410
240 Head_Flying_Hours P----- 100 100 001 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
Device Error Count: 631 (device log contains only the most recent 256 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 631 [118] occurred at disk power-on lifetime: 9900 hours (412 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 06 d0 f0 f9 e6 00 Error: UNC 1 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 d0 f0 f8 d0 f0 f9 e6 00 01:30:45.250 READ DMA
c8 00 00 00 01 d0 f0 f7 d0 f0 f8 e6 00 01:30:45.250 READ DMA
c8 00 00 00 01 d0 f0 f6 d0 f0 f7 e6 00 01:30:45.250 READ DMA
c8 00 00 00 01 d0 f0 f5 d0 f0 f6 e6 00 01:30:45.250 READ DMA
c8 00 00 00 01 d0 f0 f4 d0 f0 f5 e6 00 01:30:45.250 READ DMA
Error 630 [117] occurred at disk power-on lifetime: 9900 hours (412 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 07 00 00 06 d0 f0 f9 e6 00 Error: UNC 7 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 00 d0 ef ff d0 f0 00 e6 00 01:13:32.127 READ DMA
c8 00 00 00 00 d0 ee ff d0 ef 00 e6 00 01:13:32.121 READ DMA
c8 00 00 00 00 d0 ed ff d0 ee 00 e6 00 01:13:32.114 READ DMA
c8 00 00 00 00 d0 ec ff d0 ed 00 e6 00 01:13:32.108 READ DMA
c8 00 00 00 00 d0 eb ff d0 ec 00 e6 00 01:13:32.106 READ DMA
Error 629 [116] occurred at disk power-on lifetime: 9897 hours (412 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 01 00 00 06 d0 f0 f9 e6 00 Error: UNC 257 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 01 01 d0 f0 f9 d0 f0 f9 e6 00 01:45:41.538 READ DMA
c8 00 00 01 01 d0 f0 f9 d0 f0 f9 e6 00 01:45:32.610 READ DMA
c8 00 00 00 01 d0 f0 f8 d0 f0 f9 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f7 d0 f0 f8 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f6 d0 f0 f7 e6 00 01:45:03.719 READ DMA
Error 628 [115] occurred at disk power-on lifetime: 9897 hours (412 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 01 00 00 06 d0 f0 f9 e6 00 Error: UNC 257 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 01 01 d0 f0 f9 d0 f0 f9 e6 00 01:45:32.610 READ DMA
c8 00 00 00 01 d0 f0 f8 d0 f0 f9 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f7 d0 f0 f8 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f6 d0 f0 f7 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f5 d0 f0 f6 e6 00 01:45:03.719 READ DMA
Error 627 [114] occurred at disk power-on lifetime: 9897 hours (412 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 06 d0 f0 f9 e6 00 Error: UNC 1 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 d0 f0 f8 d0 f0 f9 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f7 d0 f0 f8 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f6 d0 f0 f7 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f5 d0 f0 f6 e6 00 01:45:03.719 READ DMA
c8 00 00 00 01 d0 f0 f4 d0 f0 f5 e6 00 01:45:03.719 READ DMA
Error 626 [113] occurred at disk power-on lifetime: 9896 hours (412 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 07 00 00 06 d0 f0 f9 e6 00 Error: UNC 7 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 00 d0 ef ff d0 f0 00 e6 00 01:35:24.906 READ DMA
c8 00 00 00 00 d0 ee ff d0 ef 00 e6 00 01:35:24.900 READ DMA
c8 00 00 00 00 d0 ed ff d0 ee 00 e6 00 01:35:24.892 READ DMA
c8 00 00 00 00 d0 ec ff d0 ed 00 e6 00 01:35:24.887 READ DMA
c8 00 00 00 00 d0 eb ff d0 ec 00 e6 00 01:35:24.879 READ DMA
Error 625 [112] occurred at disk power-on lifetime: 9452 hours (393 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 4f 00 00 06 d0 f0 f9 e6 00 Error: UNC 79 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 00 3c 78 ff d0 f0 48 e6 00 02:16:01.691 READ DMA
ca 00 00 00 20 b4 81 bf 3c 78 e0 e5 00 02:16:01.683 WRITE DMA
c8 00 00 00 20 3c 78 df b4 81 a0 e1 00 02:16:01.679 READ DMA
ca 00 00 00 40 b4 23 4f 3c 78 a0 e5 00 02:16:01.679 WRITE DMA
c8 00 00 00 40 3c 78 9f b4 23 10 e1 00 02:16:01.666 READ DMA
Error 624 [111] occurred at disk power-on lifetime: 9434 hours (393 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 4f 00 00 06 d0 f0 f9 e6 00 Error: UNC 79 sectors at LBA = 0x06d0f0f9 = 114356473
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 00 80 5c 6f d0 f0 48 e6 00 00:58:56.213 READ DMA
ca 00 00 00 38 83 21 47 80 5c 38 e1 00 00:58:56.198 WRITE DMA
c8 00 00 00 38 83 21 2f 83 21 10 e1 00 00:58:56.174 READ DMA
ca 00 00 00 08 30 eb b7 83 21 28 e1 00 00:58:56.174 WRITE DMA
ca 00 00 00 08 31 0d 47 30 eb b0 e0 00 00:58:56.050 WRITE DMA
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 6 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC