smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Toshiba 2.5" HDD MK..34GSX
Device Model: TOSHIBA MK8034GSX
Serial Number: --
Firmware Version: AH301D
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Thu May 11 15:40:41 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 61) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
2 Throughput_Performance --S--- 100 100 000 - 0
3 Spin_Up_Time POS--K 100 100 001 - 1889
4 Start_Stop_Count -O--CK 100 100 000 - 5138
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
7 Seek_Error_Rate -O-R-- 100 100 000 - 0
8 Seek_Time_Performance --S--- 100 100 000 - 0
9 Power_On_Hours -O--CK 068 068 000 - 13057
10 Spin_Retry_Count -O--CK 202 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 4274
192 Power-Off_Retract_Count -O--CK 100 100 000 - 186
193 Load_Cycle_Count -O--CK 042 042 000 - 580895
194 Temperature_Celsius -O---K 100 100 000 - 30 (Min/Max 2/60)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 17
220 Disk_Shift -O---- 100 100 000 - 4328
222 Loaded_Hours -O--CK 079 079 000 - 8620
223 Load_Retry_Count -O--CK 100 100 000 - 0
224 Load_Friction -O---K 100 100 000 - 0
226 Load-in_Time -OS--K 100 100 000 - 410
240 Head_Flying_Hours ------ 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
Device Error Count: 265 (device log contains only the most recent 256 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 265 [8] occurred at disk power-on lifetime: 12598 hours (524 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 41 00 b2 00 00 00 00 80 00 40 00 Error: ICRC, ABRT at LBA = 0x00008000 = 32768
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 01 00 00 b0 00 00 00 00 80 00 40 00 02:42:47.277 READ FPDMA QUEUED
60 01 00 00 a8 00 00 00 00 00 22 40 00 02:42:47.277 READ FPDMA QUEUED
60 01 00 00 a0 00 00 00 00 00 00 40 00 02:42:47.277 READ FPDMA QUEUED
e7 00 00 00 00 00 80 ff 00 00 00 a0 00 02:42:47.271 FLUSH CACHE
60 01 00 00 b0 00 00 00 00 80 00 40 00 02:42:47.123 READ FPDMA QUEUED
Error 264 [7] occurred at disk power-on lifetime: 12598 hours (524 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 41 00 b2 00 00 00 00 80 00 40 00 Error: ICRC, ABRT at LBA = 0x00008000 = 32768
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 01 00 00 b0 00 00 00 00 80 00 40 00 02:42:47.277 READ FPDMA QUEUED
60 01 00 00 a8 00 00 00 00 00 22 40 00 02:42:47.277 READ FPDMA QUEUED
60 01 00 00 a0 00 00 00 00 00 00 40 00 02:42:47.277 READ FPDMA QUEUED
e7 00 00 00 00 00 80 ff 00 00 00 a0 00 02:42:47.271 FLUSH CACHE
60 01 00 00 b0 00 00 00 00 80 00 40 00 02:42:47.123 READ FPDMA QUEUED
Error 263 [6] occurred at disk power-on lifetime: 12555 hours (523 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 41 00 ba 00 00 00 0e 81 cf 40 00 Error: ICRC, ABRT at LBA = 0x000e81cf = 950735
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 7f ff 00 b8 00 00 00 0e 81 cf 40 00 00:10:11.152 READ FPDMA QUEUED
60 00 10 00 c0 00 00 00 0e 81 c0 40 00 00:10:11.141 READ FPDMA QUEUED
60 00 10 00 b0 00 00 00 10 98 90 40 00 00:10:11.130 READ FPDMA QUEUED
60 1c 08 00 a8 00 00 00 10 7c 97 40 00 00:10:11.017 READ FPDMA QUEUED
60 18 24 00 98 00 00 00 10 64 73 40 00 00:10:10.917 READ FPDMA QUEUED
Error 262 [5] occurred at disk power-on lifetime: 12555 hours (523 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 41 00 ba 00 00 00 0e 81 cf 40 00 Error: ICRC, ABRT at LBA = 0x000e81cf = 950735
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 7f ff 00 b8 00 00 00 0e 81 cf 40 00 00:10:11.152 READ FPDMA QUEUED
60 00 10 00 c0 00 00 00 0e 81 c0 40 00 00:10:11.141 READ FPDMA QUEUED
60 00 10 00 b0 00 00 00 10 98 90 40 00 00:10:11.130 READ FPDMA QUEUED
60 1c 08 00 a8 00 00 00 10 7c 97 40 00 00:10:11.017 READ FPDMA QUEUED
60 18 24 00 98 00 00 00 10 64 73 40 00 00:10:10.917 READ FPDMA QUEUED
Error 261 [4] occurred at disk power-on lifetime: 12522 hours (521 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 03 d3 b3 ff e0 00 Error: ICRC, ABRT 1 sectors at LBA = 0x03d3b3ff = 64205823
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
35 00 00 00 80 00 00 03 d3 b3 80 e0 00 00:19:50.441 WRITE DMA EXT
35 00 00 00 80 00 00 03 d3 b3 00 e0 00 00:19:50.439 WRITE DMA EXT
35 00 00 00 80 00 00 03 d3 b2 80 e0 00 00:19:50.437 WRITE DMA EXT
35 00 00 00 80 00 00 03 d3 b2 00 e0 00 00:19:50.434 WRITE DMA EXT
35 00 00 00 80 00 00 03 d3 b1 80 e0 00 00:19:50.432 WRITE DMA EXT
Error 260 [3] occurred at disk power-on lifetime: 4031 hours (167 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 01 53 e9 aa e1 00 Error: ICRC, ABRT 1 sectors at LBA = 0x0153e9aa = 22276522
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 40 26 f1 2f 53 e7 b2 e1 00 00:00:07.672 READ DMA
c8 00 00 00 80 47 6b 7f 26 f0 b0 e9 00 00:00:07.648 READ DMA
c8 00 00 00 08 47 6b 77 47 6b 78 e1 00 00:00:07.571 READ DMA
c8 00 00 00 08 00 00 00 47 6b 70 e1 00 00:00:07.570 READ DMA
e7 00 00 00 00 a1 70 0f 00 00 00 a0 00 00:00:07.465 FLUSH CACHE
Error 259 [2] occurred at disk power-on lifetime: 3416 hours (142 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 02 61 58 1f e2 00 Error: ICRC, ABRT 1 sectors at LBA = 0x0261581f = 39933983
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 67 3c 2f 61 56 70 e2 00 00:39:21.370 READ DMA
c8 00 00 00 08 6c 08 b7 67 3c 28 e2 00 00:39:21.356 READ DMA
c8 00 00 00 08 69 7d 7f 6c 08 b0 e2 00 00:39:21.355 READ DMA
c8 00 00 00 08 44 1b 51 69 7d 78 e2 00 00:39:21.341 READ DMA
c8 00 00 00 08 6c 08 a7 44 1b 4a e1 00 00:39:21.332 READ DMA
Error 258 [1] occurred at disk power-on lifetime: 2551 hours (106 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 08 c5 d3 39 e8 00 Error: ICRC, ABRT 1 sectors at LBA = 0x08c5d339 = 147182393
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 48 c5 d1 57 c5 d2 d8 e8 00 00:00:10.028 READ DMA
c8 00 00 00 38 58 f7 89 c5 d1 20 e8 00 00:00:10.016 READ DMA
c8 00 00 00 40 c5 d2 d7 58 f7 4a e1 00 00:00:10.015 READ DMA
c8 00 00 00 18 c5 d2 b7 c5 d2 c0 e8 00 00:00:10.015 READ DMA
c8 00 00 00 68 58 f9 39 c5 d2 50 e8 00 00:00:10.014 READ DMA
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 1 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 1 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC