1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30
Files
2025-01-05 02:37:11 +03:00

65 lines
2.7 KiB
Plaintext

smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: INTEL SSDPEKKW128G7
Serial Number: --
Firmware Version: PSF121C
PCI Vendor/Subsystem ID: 0x8086
IEEE OUI Identifier: 0x5cd2e4
Controller ID: 1
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Local Time is: Sat Nov 18 15:29:53 2023 CET
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0006): Format Frmw_DL
Optional NVM Commands (0x001e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Maximum Data Transfer Size: 32 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.00W - - 0 0 0 0 5 5
1 + 4.60W - - 1 1 1 1 30 30
2 + 3.80W - - 2 2 2 2 30 30
3 - 0.0700W - - 3 3 3 3 10000 300
4 - 0.0050W - - 4 4 4 4 2000 10000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
- temperature is above or below threshold
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x02
Temperature: 74 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 21%
Data Units Read: 80,127,805 [41.0 TB]
Data Units Written: 58,949,388 [30.1 TB]
Host Read Commands: 2,068,347,523
Host Write Commands: 1,352,907,196
Controller Busy Time: 13,323
Power Cycles: 1,150
Power On Hours: 10,210
Unsafe Shutdowns: 646
Media and Data Integrity Errors: 1
Error Information Log Entries: 1
Warning Comp. Temperature Time: 2787
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 1 1 0x0000 0x0286 - 0 1 - Unknown Command Specific Status 0x43
Self-tests not supported