smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.3 amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: JMicron/Maxiotek based SSDs
|
|
Device Model: APPLE SSD TS128C
|
|
Serial Number: --
|
|
Firmware Version: CJAA0201
|
|
User Capacity: 121,332,826,112 bytes [121 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: Solid State Device
|
|
Form Factor: < 1.8 inches
|
|
TRIM Command: Available
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ATA8-ACS (minor revision not indicated)
|
|
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
|
Local Time is: Wed Aug 9 12:35:09 2023 CST
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART Status not supported: Incomplete response, ATA output registers missing
|
|
SMART overall-health self-assessment test result: PASSED
|
|
Warning: This result is based on an Attribute check.
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 120) seconds.
|
|
Offline data collection
|
|
capabilities: (0x5b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 12) minutes.
|
|
SCT capabilities: (0x0039) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
|
1 Raw_Read_Error_Rate 0x000a 098 098 000 Old_age Always - 0
|
|
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
|
|
3 Unknown_JMF_Attribute 0x0007 100 100 050 Pre-fail Always - 0
|
|
5 Reallocated_Sector_Ct 0x0013 100 100 050 Pre-fail Always - 0
|
|
7 Unknown_JMF_Attribute 0x000b 100 100 050 Pre-fail Always - 0
|
|
8 Unknown_JMF_Attribute 0x0005 100 100 050 Pre-fail Offline - 0
|
|
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 2151
|
|
10 Unknown_JMF_Attribute 0x0013 100 100 050 Pre-fail Always - 0
|
|
12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 4814
|
|
167 Unknown_JMF_Attribute 0x0022 100 100 000 Old_age Always - 0
|
|
168 SATA_Phy_Error_Count 0x0012 100 100 000 Old_age Always - 0
|
|
169 Unknown_JMF_Attribute 0x0013 100 100 010 Pre-fail Always - 919218029866
|
|
170 Bad_Block_Count 0x0013 100 100 010 Pre-fail Always - 59 252 82
|
|
171 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 214
|
|
173 Erase_Count 0x0013 196 196 100 Pre-fail Always - 3 133 42
|
|
175 Bad_Cluster_Table_Count 0x0013 100 100 010 Pre-fail Always - 0
|
|
192 Unexpect_Power_Loss_Ct 0x0012 100 100 000 Old_age Always - 41
|
|
194 Temperature_Celsius 0x0023 050 037 030 Pre-fail Always - 50 (Min/Max 20/63)
|
|
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
|
199 UDMA_CRC_Error_Count 0x0012 100 100 000 Old_age Always - 0
|
|
240 Unknown_JMF_Attribute 0x0013 100 100 050 Pre-fail Always - 0
|
|
|
|
SMART Error Log Version: 1
|
|
No Errors Logged
|
|
|
|
SMART Self-test log structure revision number 1
|
|
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
|
|
|