smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p18-HBSD amd64] (local build)
|
|
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: SandForce Driven SSDs
|
|
Device Model: Corsair CSSD-F60GB2
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 000000 ...
|
|
Firmware Version: 2.0
|
|
User Capacity: 60,022,480,896 bytes [60.0 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: Solid State Device
|
|
TRIM Command: Available, deterministic
|
|
Device is: In smartctl database [for details use: -P show]
|
|
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
|
SATA Version is: SATA 2.6, 3.0 Gb/s
|
|
Local Time is: Sun Jun 27 06:45:30 2021 UTC
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM feature is: Unavailable
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, frozen [SEC2]
|
|
Wt Cache Reorder: Unknown (0x100)
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 0) seconds.
|
|
Offline data collection
|
|
capabilities: (0x7f) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Abort Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 1) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 48) minutes.
|
|
Conveyance self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
SCT capabilities: (0x003d) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 10
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
|
|
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
|
9 Power_On_Hours_and_Msec -O--CK 100 100 000 - 12404h+18m+25.140s
|
|
12 Power_Cycle_Count -O--CK 100 100 000 - 673
|
|
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
|
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
|
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 366
|
|
177 Wear_Range_Delta ------ 000 000 --- - 1
|
|
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
|
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
|
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
|
194 Temperature_Celsius -O---K 037 056 000 - 37 (Min/Max 0/56)
|
|
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/0
|
|
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
|
231 SSD_Life_Left PO--C- 100 100 010 - 0
|
|
233 SandForce_Internal ------ 000 000 000 - 1472
|
|
234 SandForce_Internal -O--CK 000 000 000 - 2368
|
|
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 2368
|
|
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 5312
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 1
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x07 GPL R/O 1 Extended self-test log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
|
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|
0xb7 GPL,SL VS 16 Device vendor specific log
|
|
0xe0 GPL,SL R/W 1 SCT Command/Status
|
|
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
|
|
|
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
|
|
|
SMART Error Log not supported
|
|
|
|
SMART Extended Self-test Log Version: 1 (1 sectors)
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Extended offline Self-test routine in progress 90% 11682 -
|
|
# 2 Extended offline Self-test routine in progress 90% 10322 -
|
|
# 3 Short offline Self-test routine in progress 90% 2230 -
|
|
# 4 Short offline Self-test routine in progress 90% 2217 -
|
|
# 5 Short offline Self-test routine in progress 90% 2217 -
|
|
# 6 Short offline Self-test routine in progress 90% 805 -
|
|
# 7 Short offline Self-test routine in progress 90% 0 -
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Status Version: 3
|
|
SCT Version (vendor specific): 0 (0x0000)
|
|
Device State: Active (0)
|
|
Current Temperature: 37 Celsius
|
|
Power Cycle Min/Max Temperature: 27/37 Celsius
|
|
Lifetime Min/Max Temperature: 0/56 Celsius
|
|
Under/Over Temperature Limit Count: 0/0
|
|
|
|
SCT Temperature History Version: 2
|
|
Temperature Sampling Period: 1 minute
|
|
Temperature Logging Interval: 1 minute
|
|
Min/Max recommended Temperature: ?/ ? Celsius
|
|
Min/Max Temperature Limit: ?/ ? Celsius
|
|
Temperature History Size (Index): 478 (384)
|
|
|
|
SCT Error Recovery Control:
|
|
Read: 256 (25.6 seconds)
|
|
Write: 256 (25.6 seconds)
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11)
|
|
ID Size Value Description
|
|
0x0001 2 0 Command failed due to ICRC error
|
|
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
|
|