smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: INTEL SSDMAEMC040G2
Serial Number: --
LU WWN Device Id: 5 001517 ...
Firmware Version: 2CV102M3
User Capacity: 40,020,664,320 bytes [40.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available, deterministic, zeroed
Device is: Not in smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri Dec 27 17:00:38 2024 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 16) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 1) seconds.
Offline data collection
capabilities: (0x71) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 1) minutes.
Conveyance self-test routine
recommended polling time: ( 1) minutes.
SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
3 Spin_Up_Time -----K 100 100 000 - 0
4 Start_Stop_Count ----CK 100 100 000 - 0
5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0
9 Power_On_Hours -O--CK 100 100 000 - 32933
12 Power_Cycle_Count -O--CK 100 100 000 - 817
192 Power-Off_Retract_Count -O--CK 100 100 000 - 170
225 Unknown_SSD_Attribute ----CK 100 100 000 - 184451
226 Unknown_SSD_Attribute -O--CK 100 100 000 - 21199861
227 Unknown_SSD_Attribute -O--CK 100 100 000 - 0
228 Power-off_Retract_Count -O--CK 100 100 000 - 4166707638
232 Available_Reservd_Space PO--CK 100 100 010 - 0
233 Media_Wearout_Indicator -O--CK 094 094 000 - 0
184 End-to-End_Error PO--CK 100 100 090 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 8 Comprehensive SMART error log
0x03 GPL,SL R/O 8 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (8 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Invalid Self-test Log index = 0x00a0 (reserved = 0x00)
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 68 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 69 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC