1
0
mirror of https://github.com/bsdhw/SMART.git synced 2026-04-25 00:32:22 +05:30
Files
2022-03-18 23:39:11 +03:00

91 lines
4.2 KiB
Plaintext

smartctl 7.2 2020-12-30 r5155 [OpenBSD 7.0 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Intel X18-M/X25-M/X25-V G2 SSDs
Device Model: INTEL SSDSA2M080G2GC
Serial Number: --
LU WWN Device Id: 5 001517 ...
Firmware Version: 2CV102M3
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sun Nov 14 21:04:45 2021 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1) seconds.
Offline data collection
capabilities: (0x71) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 1) minutes.
Conveyance self-test routine
recommended polling time: ( 1) minutes.
SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
3 Spin_Up_Time 0x0020 100 100 000 Old_age Offline - 0
4 Start_Stop_Count 0x0030 100 100 000 Old_age Offline - 0
5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 4
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 62683
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1369
192 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 683
225 Host_Writes_32MiB 0x0030 100 100 000 Old_age Offline - 647617
226 Workld_Media_Wear_Indic 0x0032 100 100 000 Old_age Always - 50832
227 Workld_Host_Reads_Perc 0x0032 100 100 000 Old_age Always - 1
228 Workload_Minutes 0x0032 100 100 000 Old_age Always - 20473464
232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
233 Media_Wearout_Indicator 0x0032 092 092 000 Old_age Always - 0
184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.