smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: KINGSTON SV300S37A120G
Serial Number: --
LU WWN Device Id: 5 0026b7 ...
Firmware Version: 541ABBF0
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is: Thu May 5 18:29:22 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0025) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 098 098 000 - 2539h+55m+14.650s
12 Power_Cycle_Count -O--CK 098 098 000 - 2617
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 1939
177 Wear_Range_Delta ------ 000 000 000 - 1
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 028 050 000 - 28 (Min/Max 8/50)
194 Temperature_Celsius -O---K 028 050 000 - 28 (Min/Max 8/50)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/0
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 100 100 010 - 0
233 SandForce_Internal -O--CK 000 000 000 - 2322
234 SandForce_Internal -O--CK 000 000 000 - 3023
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 3023
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 1614
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented [JMicron]
Read GP Log Directory failed
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x04 SL R/O 16 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x09 SL R/W 1 Selective self-test log
0x80-0x9f SL R/W 16 Host vendor specific log
0xb7 SL VS 16 Device vendor specific log
0xe0 SL R/W 1 SCT Command/Status
0xe1 SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 8/50 Celsius
Lifetime Min/Max Temperature: 8/63 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (173)
SCT Error Recovery Control command not supported
Device Statistics (SMART Log 0x04)
Page Offset Size Value Flags Description
ATA_SMART_READ_LOG failed: Multi-sector ATA commands not implemented [JMicron]
Read Device Statistics pages 0x00-0x07 failed
Pending Defects log (GP Log 0x0c) not supported
ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented [JMicron]
Read SATA Phy Event Counters failed