smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SSD G2 series 64GB
Serial Number: --
LU WWN Device Id: 5 000000 ...
Firmware Version: 3.4.6
User Capacity: 60,022,480,896 bytes [60.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available, deterministic
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Wed Feb 2 18:56:54 2022 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unknown (0x100)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7f) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0
5 Reallocated_Sector_Ct PO--CK 100 100 003 - 0
9 Power_On_Hours -O--CK 100 100 000 - 31138 (205 44 0)
12 Power_Cycle_Count -O--CK 099 099 000 - 1497
171 Unknown_Attribute -O--CK 000 000 000 - 0
172 Unknown_Attribute -O--CK 000 000 000 - 0
174 Unknown_Attribute ----CK 000 000 000 - 602
177 Wear_Leveling_Count ------ 000 000 --- - 1
181 Program_Fail_Cnt_Total -O--CK 000 000 000 - 0
182 Erase_Fail_Count_Total -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 073 091 000 - 73 (Min/Max 0/91)
195 Hardware_ECC_Recovered --SRC- 120 120 000 - 0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
231 Unknown_SSD_Attribute PO--C- 100 100 010 - 0
233 Media_Wearout_Indicator ------ 000 000 000 - 1792
234 Unknown_Attribute -O--CK 000 000 000 - 2048
241 Total_LBAs_Written -O--CK 000 000 000 - 2048
242 Total_LBAs_Read -O--CK 000 000 000 - 4160
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xb7 GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Self-test routine in progress 90% 4738 -
# 2 Short offline Self-test routine in progress 90% 4737 -
# 3 Short offline Self-test routine in progress 90% 4580 -
# 4 Extended offline Self-test routine in progress 90% 4560 -
# 5 Short offline Self-test routine in progress 90% 4559 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 73 Celsius
Power Cycle Min/Max Temperature: 56/77 Celsius
Lifetime Min/Max Temperature: 0/91 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 478 (479)
Invalid Temperature History Size or Index
SCT Error Recovery Control:
Read: 256 (25.6 seconds)
Write: 256 (25.6 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 26 Device-to-host register FISes sent due to a COMRESET