mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
229 lines
11 KiB
Plaintext
229 lines
11 KiB
Plaintext
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
|
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Device Model: P300-MTFDBAC050SAL
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 00a075 ...
|
|
Firmware Version: 0001
|
|
User Capacity: 50,020,540,416 bytes [50.0 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: Solid State Device
|
|
Form Factor: 2.5 inches
|
|
TRIM Command: Available, deterministic
|
|
Device is: Not in smartctl database [for details use: -P showall]
|
|
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
|
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
|
Local Time is: Sun Mar 21 21:34:49 2021 CET
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM level is: 254 (maximum performance)
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, frozen [SEC2]
|
|
Wt Cache Reorder: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x80) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Enabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 230) seconds.
|
|
Offline data collection
|
|
capabilities: (0x7b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 3) minutes.
|
|
Conveyance self-test routine
|
|
recommended polling time: ( 3) minutes.
|
|
SCT capabilities: (0x003d) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate -O--CK 100 100 000 - 0
|
|
5 Reallocated_Sector_Ct -O--CK 100 100 000 - 12288
|
|
6 Unknown_SSD_Attribute -O--CK 100 100 000 - 1536
|
|
7 Unknown_SSD_Attribute -O--CK 100 100 000 - 12
|
|
9 Power_On_Hours -O--CK 100 100 000 - 26686
|
|
11 Unknown_SSD_Attribute -O--C- 100 100 000 - 0
|
|
12 Power_Cycle_Count -O--CK 100 100 000 - 33
|
|
13 Read_Soft_Error_Rate ------ 100 100 000 - 0
|
|
15 Unknown_Attribute ------ 100 100 000 - 50
|
|
170 Unknown_Attribute -O--CK 100 100 000 - 35479
|
|
171 Unknown_Attribute -O--CK 100 100 000 - 0
|
|
172 Unknown_Attribute -O--CK 100 100 000 - 0
|
|
173 Unknown_Attribute -O--CK 100 100 000 - 76
|
|
174 Unknown_Attribute -O--CK 100 100 000 - 0
|
|
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 243
|
|
181 Program_Fail_Cnt_Total P---C- 100 100 000 - 605599105031
|
|
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
|
184 End-to-End_Error -O--CK 100 100 000 - 0
|
|
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
|
188 Command_Timeout -O--CK 100 100 000 - 0
|
|
189 Unknown_SSD_Attribute -OSR-- 100 100 000 - 12
|
|
190 Airflow_Temperature_Cel -O---K 054 041 000 - 46 (Min/Max 22/59)
|
|
194 Temperature_Celsius -O--C- 056 041 000 - 44 (Min/Max 22/59)
|
|
195 Hardware_ECC_Recovered --SRCK 100 100 000 - 0
|
|
196 Reallocated_Event_Count -O--CK 100 100 000 - 12
|
|
197 Current_Pending_Sector -O--CK 100 100 000 - 100
|
|
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
|
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
|
202 Unknown_SSD_Attribute ---RC- 100 100 000 - 0
|
|
206 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 1
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 51 Comprehensive SMART error log
|
|
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
|
0x04 GPL,SL R/O 255 Device Statistics log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 GPL R/O 3449 Extended self-test log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x11 GPL R/O 1 SATA Phy Event Counters log
|
|
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|
0xa0 GPL VS 1492 Device vendor specific log
|
|
0xa0 SL VS 212 Device vendor specific log
|
|
0xbf SL VS 1 Device vendor specific log
|
|
0xe0 GPL,SL R/W 1 SCT Command/Status
|
|
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
|
|
|
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
|
No Errors Logged
|
|
|
|
SMART Extended Self-test Log size 3449 not supported
|
|
|
|
SMART Self-test log structure revision number 1
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Vendor (0xff) Completed without error 00% 10623 -
|
|
# 2 Vendor (0xff) Completed without error 00% 10611 -
|
|
# 3 Vendor (0xff) Completed without error 00% 10598 -
|
|
# 4 Vendor (0xff) Completed without error 00% 10586 -
|
|
# 5 Vendor (0xff) Completed without error 00% 10574 -
|
|
# 6 Vendor (0xff) Completed without error 00% 10561 -
|
|
# 7 Vendor (0xff) Completed without error 00% 10549 -
|
|
# 8 Vendor (0xff) Completed without error 00% 10537 -
|
|
# 9 Vendor (0xff) Completed without error 00% 10524 -
|
|
#10 Vendor (0xff) Completed without error 00% 10512 -
|
|
#11 Vendor (0xff) Completed without error 00% 10500 -
|
|
#12 Vendor (0xff) Completed without error 00% 10487 -
|
|
#13 Vendor (0xff) Completed without error 00% 10475 -
|
|
#14 Vendor (0xff) Completed without error 00% 10463 -
|
|
#15 Vendor (0xff) Completed without error 00% 10450 -
|
|
#16 Vendor (0xff) Completed without error 00% 10438 -
|
|
#17 Vendor (0xff) Completed without error 00% 10426 -
|
|
#18 Vendor (0xff) Completed without error 00% 10413 -
|
|
#19 Vendor (0xff) Completed without error 00% 10401 -
|
|
#20 Vendor (0xff) Completed without error 00% 10389 -
|
|
#21 Vendor (0xff) Completed without error 00% 10376 -
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Status Version: 3
|
|
SCT Version (vendor specific): 1 (0x0001)
|
|
Device State: Active (0)
|
|
Current Temperature: 46 Celsius
|
|
Power Cycle Min/Max Temperature: 27/46 Celsius
|
|
Lifetime Min/Max Temperature: 22/58 Celsius
|
|
Under/Over Temperature Limit Count: 0/0
|
|
|
|
SCT Temperature History Version: 2
|
|
Temperature Sampling Period: 10 minutes
|
|
Temperature Logging Interval: 10 minutes
|
|
Min/Max recommended Temperature: 0/70 Celsius
|
|
Min/Max Temperature Limit: -5/75 Celsius
|
|
Temperature History Size (Index): 478 (102)
|
|
|
|
SCT Error Recovery Control:
|
|
Read: 40 (4.0 seconds)
|
|
Write: 40 (4.0 seconds)
|
|
|
|
Device Statistics (GP Log 0x04)
|
|
Page Offset Size Value Flags Description
|
|
0x01 ===== = = === == General Statistics (rev 2) ==
|
|
0x01 0x008 4 33 --- Lifetime Power-On Resets
|
|
0x01 0x010 4 26686 --- Power-on Hours
|
|
0x01 0x018 6 9539187736 --- Logical Sectors Written
|
|
0x01 0x020 6 127820924 --- Number of Write Commands
|
|
0x01 0x028 6 423764795 --- Logical Sectors Read
|
|
0x01 0x030 6 2378926 --- Number of Read Commands
|
|
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
|
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
|
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
|
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
|
0x05 0x008 1 42 --- Current Temperature
|
|
0x05 0x010 1 37 --- Average Short Term Temperature
|
|
0x05 0x018 1 37 --- Average Long Term Temperature
|
|
0x05 0x020 1 59 --- Highest Temperature
|
|
0x05 0x028 1 22 --- Lowest Temperature
|
|
0x05 0x030 1 50 --- Highest Average Short Term Temperature
|
|
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
|
0x05 0x040 1 46 --- Highest Average Long Term Temperature
|
|
0x05 0x048 1 34 --- Lowest Average Long Term Temperature
|
|
0x05 0x050 4 - --- Time in Over-Temperature
|
|
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
|
0x05 0x060 4 - --- Time in Under-Temperature
|
|
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
|
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
|
0x06 0x008 4 0 --- Number of Hardware Resets
|
|
0x06 0x010 4 0 --- Number of ASR Events
|
|
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
|
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
|
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|
|
|||_ C monitored condition met
|
|
||__ D supports DSN
|
|
|___ N normalized value
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11)
|
|
ID Size Value Description
|
|
0x0001 4 0 Command failed due to ICRC error
|
|
0x000a 4 31 Device-to-host register FISes sent due to a COMRESET
|
|
|
|
|
|
|