smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: SK hynix SATA SSDs
|
|
Device Model: HFS128G39MND-3310A
|
|
Serial Number: --
|
|
Firmware Version: 20002P00
|
|
User Capacity: 128,035,676,160 bytes [128 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: Solid State Device
|
|
TRIM Command: Available, deterministic
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ATA8-ACS (minor revision not indicated)
|
|
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
|
Local Time is: Fri May 26 12:26:33 2023 PDT
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM level is: 254 (maximum performance)
|
|
Rd look-ahead is: Unavailable
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, frozen [SEC2]
|
|
Wt Cache Reorder: Unavailable
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x02) Offline data collection activity
|
|
was completed without error.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 463) seconds.
|
|
Offline data collection
|
|
capabilities: (0x59) SMART execute Offline immediate.
|
|
No Auto Offline data collection support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0002) Does not save SMART data before
|
|
entering power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 1) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
|
|
SMART Attributes Data Structure revision number: 0
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-- 166 166 006 - 0
|
|
5 Retired_Block_Count -O--CK 253 253 036 - 0
|
|
9 Power_On_Hours -O--CK 096 096 000 - 4398
|
|
12 Power_Cycle_Count -O--CK 100 100 020 - 4330
|
|
100 Total_Erase_Count -O--CK 100 100 000 - 3241491
|
|
170 Unknown_SK_hynix_Attrib -O--CK 100 100 000 - 22
|
|
171 Program_Fail_Count -O--CK 253 253 000 - 0
|
|
172 Erase_Fail_Count -O--CK 253 253 000 - 0
|
|
173 Wear_Leveling_Count -O--CK 097 097 000 - 91
|
|
174 Unexpect_Power_Loss_Ct ----CK 100 100 000 - 748
|
|
177 Wear_Leveling_Count -O--CK 097 097 000 - 91
|
|
178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 000 - 22
|
|
180 Erase_Fail_Count -O--CK 100 100 000 - 1946
|
|
181 Non4k_Aligned_Access -O--CK 253 253 000 - 0
|
|
182 Erase_Fail_Count_Total -O--CK 253 253 000 - 0
|
|
183 SATA_Downshift_Count -O--CK 253 253 000 - 0
|
|
184 End-to-End_Error -O--CK 253 253 000 - 0
|
|
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
|
194 Temperature_Celsius -O---- 035 000 000 - 35 (Min/Max 17/64)
|
|
195 Hardware_ECC_Recovered -O--CK 253 253 000 - 0
|
|
199 UDMA_CRC_Error_Count -O--CK 253 253 000 - 0
|
|
201 Percent_Lifetime_Remain -OSR-- 100 100 000 - 0
|
|
204 Soft_ECC_Correction -OSR-- 100 100 000 - 0
|
|
231 SSD_Life_Left PO--CK 253 253 010 - 0
|
|
233 Media_Wearout_Indicator -O--CK 100 100 000 - 11031
|
|
234 Unknown_SK_hynix_Attrib -O--CK 100 100 --- - 11031
|
|
241 Total_Writes_GB -O--CK 100 100 --- - 5561
|
|
242 Total_Reads_GB -O--CK 100 100 --- - 10455
|
|
250 Read_Retry_Count -O--CK 100 100 --- - 39473
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 1
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 4 Comprehensive SMART error log
|
|
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
|
0x04 GPL,SL R/O 8 Device Statistics log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 GPL R/O 2 Extended self-test log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x11 GPL R/O 1 SATA Phy Event Counters log
|
|
0x30 GPL R/O 8 IDENTIFY DEVICE data log
|
|
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|
|
|
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
|
No Errors Logged
|
|
|
|
Warning! SMART Extended Self-test Log Structure (1/2) error: invalid SMART checksum.
|
|
SMART Extended Self-test Log Version: 1 (2 sectors)
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Extended offline Completed without error 00% 3200 -
|
|
# 2 Short offline Completed without error 00% 3198 -
|
|
# 3 Short offline Completed without error 00% 3196 -
|
|
# 4 Short offline Completed without error 00% 3189 -
|
|
# 5 Short offline Completed without error 00% 3173 -
|
|
# 6 Extended offline Completed without error 00% 3171 -
|
|
# 7 Short offline Completed without error 00% 3163 -
|
|
# 8 Short offline Completed without error 00% 3140 -
|
|
# 9 Short offline Completed without error 00% 3117 -
|
|
#10 Short offline Completed without error 00% 3094 -
|
|
#11 Short offline Completed without error 00% 3070 -
|
|
#12 Short offline Completed without error 00% 3059 -
|
|
#13 Short offline Completed without error 00% 3058 -
|
|
#14 Extended offline Completed without error 00% 3053 -
|
|
#15 Short offline Completed without error 00% 3051 -
|
|
#16 Short offline Completed without error 00% 3046 -
|
|
#17 Short offline Completed without error 00% 3043 -
|
|
#18 Short offline Completed without error 00% 3040 -
|
|
#19 Short offline Completed without error 00% 1942 -
|
|
#20 Short offline Completed without error 00% 1942 -
|
|
|
|
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
|
|
SMART Selective self-test log data structure revision number 0
|
|
Note: revision number not 1 implies that no selective self-test has ever been run
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Commands not supported
|
|
|
|
Device Statistics (GP Log 0x04)
|
|
Page Offset Size Value Flags Description
|
|
0x01 ===== = = === == General Statistics (empty) ==
|
|
0x04 ===== = = === == General Errors Statistics (empty) ==
|
|
0x05 ===== = = === == Temperature Statistics (empty) ==
|
|
0x06 ===== = = === == Transport Statistics (empty) ==
|
|
0x07 ===== = = === == Solid State Device Statistics (empty) ==
|
|
|||_ C monitored condition met
|
|
||__ D supports DSN
|
|
|___ N normalized value
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11)
|
|
ID Size Value Description
|
|
0x0001 2 0 Command failed due to ICRC error
|
|
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
|
|