smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.9] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: 3E128-TS2-550B01
Serial Number: --
LU WWN Device Id: 5 001173 ...
Firmware Version: PRO6UI39
User Capacity: 100,000,000,512 bytes [100 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jun 7 19:22:09 2021 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0025) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0033 120 120 050 Pre-fail Always - 34359738368
5 Reallocated_Sector_Ct 0x0033 100 100 003 Pre-fail Always - 0
9 Power_On_Hours 0x0032 000 000 000 Old_age Always - 14251 (202 0 0)
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 245
13 Read_Soft_Error_Rate 0x0032 120 120 000 Old_age Always - 253287106347008
100 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 2547
170 Unknown_Attribute 0x00ef 000 000 000 Pre-fail Always - 35072
171 Unknown_Attribute 0x000a 000 000 000 Old_age Always - 0
172 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 0
174 Unknown_Attribute 0x0030 000 000 000 Old_age Offline - 251
177 Wear_Leveling_Count 0x0000 000 000 000 Old_age Offline - 0
181 Program_Fail_Cnt_Total 0x000a 000 000 000 Old_age Always - 0
182 Erase_Fail_Count_Total 0x0032 000 000 000 Old_age Always - 0
184 End-to-End_Error 0x0000 100 100 090 Old_age Offline - 0
187 Reported_Uncorrect 0x001c 100 100 000 Old_age Offline - 0
194 Temperature_Celsius 0x0022 046 059 000 Old_age Always - 46 (Min/Max 16/59)
195 Hardware_ECC_Recovered 0x001c 100 100 000 Old_age Offline - 34359738368
196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0
198 Offline_Uncorrectable 0x0010 120 120 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0004 200 200 000 Old_age Offline - 0
201 Unknown_SSD_Attribute 0x001c 100 100 000 Old_age Offline - 34359738368
204 Soft_ECC_Correction 0x001c 100 100 000 Old_age Offline - 34359738368
230 Unknown_SSD_Attribute 0x0013 100 100 000 Pre-fail Always - 100
231 Temperature_Celsius 0x0013 100 100 010 Pre-fail Always - 0
232 Available_Reservd_Space 0x0032 000 000 000 Old_age Always - 34
233 Media_Wearout_Indicator 0x0032 000 000 000 Old_age Always - 2246
234 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 9605
241 Total_LBAs_Written 0x0032 000 000 000 Old_age Always - 9605
242 Total_LBAs_Read 0x0032 000 000 000 Old_age Always - 173907
SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.