1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30
Files
SMART-open-study/HDD/Samsung/HD501/HD501LJ/D37BC44F1A91
2020-06-01 15:47:06 +03:00

306 lines
15 KiB
Plaintext

smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint T166
Device Model: SAMSUNG HD501LJ
Serial Number: --
LU WWN Device Id: 5 0000f0 ...
Firmware Version: CR100-12
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 3b
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Mon May 25 14:01:48 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 254
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 9041) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 154) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
3 Spin_Up_Time POS--- 100 100 015 - 7232
4 Start_Stop_Count -O--CK 100 100 000 - 372
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 2
7 Seek_Error_Rate POSR-- 253 253 051 - 0
8 Seek_Time_Performance P-S--K 253 253 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 88771
10 Spin_Retry_Count PO--CK 253 253 051 - 0
11 Calibration_Retry_Count -O--C- 253 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 351
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 188191809
187 Reported_Uncorrect -O--CK 253 253 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 8
190 Airflow_Temperature_Cel -O---K 070 053 000 - 30
194 Temperature_Celsius -O---K 148 097 000 - 30
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 188191809
196 Reallocated_Event_Count -O--CK 100 100 000 - 2
197 Total_Pending_Sectors -O--C- 253 100 000 - 0
198 Offline_Uncorrectable ----CK 253 253 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Invalid Error Log index = 0x0000, trying reserved byte (0x02) instead
Device Error Count: 42 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 42 [1] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 07 40 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 80 02 07 40 00 00 0a 62 74 54 40 00 29d+04:17:16.379 WRITE FPDMA QUEUED
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:17:10.566 READ LOG EXT
Error 41 [0] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 03 20 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 80 02 03 20 00 00 0a 62 74 54 40 00 29d+04:17:10.441 WRITE FPDMA QUEUED
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:17:04.629 READ LOG EXT
Error 40 [7] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 1f 00 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 80 02 1f 00 00 00 0a 62 74 54 40 00 29d+04:17:04.566 WRITE FPDMA QUEUED
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:16:58.379 READ LOG EXT
Error 39 [6] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 1b e0 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 80 02 1b e0 00 00 0a 62 74 54 40 00 29d+04:16:58.316 WRITE FPDMA QUEUED
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:16:53.129 READ LOG EXT
Error 38 [5] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 14 a0 00 00 01 6a 42 80 40 00 Error: UNC at LBA = 0x016a4280 = 23741056
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 80 80 14 a0 00 00 01 6a 42 80 40 00 29d+04:16:53.004 READ FPDMA QUEUED
60 80 80 14 a0 00 00 01 6a 42 00 40 00 29d+04:16:46.879 READ FPDMA QUEUED
60 80 80 14 a0 00 00 01 6a 41 80 40 00 29d+04:16:46.879 READ FPDMA QUEUED
60 80 80 14 a0 00 00 01 6a 41 00 40 00 29d+04:16:46.879 READ FPDMA QUEUED
60 80 80 14 a0 00 00 01 6a 40 80 40 00 29d+04:16:46.879 READ FPDMA QUEUED
Error 37 [4] occurred at disk power-on lifetime: 28739 hours (1197 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 16 b8 00 00 0a ba 55 38 40 00 Error: WP at LBA = 0x0aba5538 = 179983672
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 02 16 b8 00 00 0a ba 55 38 40 00 28d+22:22:42.129 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 00 28d+22:22:36.629 READ LOG EXT
Error 36 [3] occurred at disk power-on lifetime: 28739 hours (1197 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 12 98 00 00 0a ba 55 38 40 00 Error: WP at LBA = 0x0aba5538 = 179983672
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 02 12 98 00 00 0a ba 55 38 40 00 28d+22:22:36.566 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 00 28d+22:22:29.754 READ LOG EXT
Error 35 [2] occurred at disk power-on lifetime: 28739 hours (1197 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 0e 78 00 00 0a ba 55 38 40 00 Error: WP at LBA = 0x0aba5538 = 179983672
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 02 0e 78 00 00 0a ba 55 38 40 00 28d+22:22:29.629 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 00 28d+22:22:23.816 READ LOG EXT
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 17716 -
# 2 Extended offline Completed without error 00% 6938 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 25/35 Celsius
Lifetime Min/Max Temperature: 12/47 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: -4/72 Celsius
Min/Max Temperature Limit: -9/77 Celsius
Temperature History Size (Index): 128 (58)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 66 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8001 2 0 Vendor specific