mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
103 lines
5.3 KiB
Plaintext
103 lines
5.3 KiB
Plaintext
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.2 amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: SAMSUNG SpinPoint M5
|
|
Device Model: SAMSUNG HM160HI
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 0f0000 ...
|
|
Firmware Version: HH100-15
|
|
User Capacity: 160,041,885,696 bytes [160 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 0
|
|
SATA Version is: SATA 2.5, 1.5 Gb/s
|
|
Local Time is: Sun Apr 9 14:00:44 2023 CDT
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART Status not supported: Incomplete response, ATA output registers missing
|
|
SMART overall-health self-assessment test result: PASSED
|
|
Warning: This result is based on an Attribute check.
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 56) seconds.
|
|
Offline data collection
|
|
capabilities: (0x51) SMART execute Offline immediate.
|
|
No Auto Offline data collection support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
No Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 56) minutes.
|
|
SCT capabilities: (0x003f) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
|
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
|
|
3 Spin_Up_Time 0x0007 252 252 025 Pre-fail Always - 2000
|
|
4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 3610
|
|
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 1
|
|
7 Seek_Error_Rate 0x000f 252 252 051 Pre-fail Always - 0
|
|
8 Seek_Time_Performance 0x0025 252 252 015 Pre-fail Offline - 0
|
|
9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 1569
|
|
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 7
|
|
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 406
|
|
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1840
|
|
184 End-to-End_Error 0x0033 252 252 070 Pre-fail Always - 0
|
|
187 Reported_Uncorrect 0x0032 252 252 000 Old_age Always - 0
|
|
188 Command_Timeout 0x0032 252 252 000 Old_age Always - 0
|
|
190 Airflow_Temperature_Cel 0x0022 066 048 040 Old_age Always - 34 (Min/Max 6/60)
|
|
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 1993
|
|
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 102
|
|
193 Load_Cycle_Count 0x0032 096 096 000 Old_age Always - 42514
|
|
194 Temperature_Celsius 0x0022 064 048 000 Old_age Always - 34 (Min/Max 6/60)
|
|
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 0
|
|
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
|
|
197 Current_Pending_Sector 0x0012 252 252 000 Old_age Always - 0
|
|
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
|
|
199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0
|
|
200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
|
|
201 Soft_Read_Error_Rate 0x0032 252 252 000 Old_age Always - 0
|
|
|
|
SMART Error Log Version: 1
|
|
No Errors Logged
|
|
|
|
SMART Self-test log structure revision number 1
|
|
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|
|
|
SMART Selective self-test log data structure revision number 0
|
|
Note: revision number not 1 implies that no selective self-test has ever been run
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|