smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: Seagate Momentus 5400.2
|
|
Device Model: ST96812AS
|
|
Serial Number: --
|
|
Firmware Version: 7.24
|
|
User Capacity: 60,022,480,896 bytes [60.0 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
|
Local Time is: Sat Oct 22 06:21:16 2022 CEST
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM level is: 128 (minimum power consumption without standby)
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
|
Wt Cache Reorder: Unavailable
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
See vendor-specific Attribute list for marginal Attributes.
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x82) Offline data collection activity
|
|
was completed without error.
|
|
Auto Offline Data Collection: Enabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 426) seconds.
|
|
Offline data collection
|
|
capabilities: (0x5b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
No General Purpose Logging support.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 32) minutes.
|
|
SCT capabilities: (0x0001) SCT Status supported.
|
|
|
|
SMART Attributes Data Structure revision number: 10
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-- 106 091 006 - 11062340
|
|
3 Spin_Up_Time -O---- 097 097 000 - 0
|
|
4 Start_Stop_Count PO--CK 095 095 020 - 5202
|
|
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
|
7 Seek_Error_Rate POSR-- 084 060 030 - 322129150
|
|
9 Power_On_Hours -O--CK 089 089 000 - 10367
|
|
10 Spin_Retry_Count PO--C- 100 100 034 - 0
|
|
12 Power_Cycle_Count PO--CK 097 097 020 - 3702
|
|
187 Reported_Uncorrect -O--CK 060 060 000 - 40
|
|
189 High_Fly_Writes -O-RCK 001 001 000 - 478
|
|
190 Airflow_Temperature_Cel -O---K 068 044 045 Past 32 (Min/Max 24/33)
|
|
192 Power-Off_Retract_Count -O--CK 100 100 000 - 325
|
|
193 Load_Cycle_Count -O--CK 005 005 000 - 190651
|
|
194 Temperature_Celsius -O---K 032 056 000 - 32
|
|
195 Hardware_ECC_Recovered -O-RC- 063 046 000 - 131912915
|
|
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
|
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
|
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
|
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
|
202 Data_Address_Mark_Errs ------ 100 253 000 - 0
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory not supported
|
|
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 5 Comprehensive SMART error log
|
|
0x03 SL R/O 5 Ext. Comprehensive SMART error log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 SL R/O 1 Extended self-test log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x10 SL R/O 1 NCQ Command Error log
|
|
0x11 SL R/O 1 SATA Phy Event Counters log
|
|
0x20 SL R/O 1 Streaming performance log [OBS-8]
|
|
0x21 SL R/O 1 Write stream error log
|
|
0x22 SL R/O 1 Read stream error log
|
|
0x23 SL R/O 1 Delayed sector log [OBS-8]
|
|
0x80-0x9f SL R/W 16 Host vendor specific log
|
|
0xa0 SL VS 1 Device vendor specific log
|
|
0xa1 SL VS 20 Device vendor specific log
|
|
0xa2 SL VS 101 Device vendor specific log
|
|
0xa8 SL VS 20 Device vendor specific log
|
|
0xa9 SL VS 1 Device vendor specific log
|
|
0xe0 SL R/W 1 SCT Command/Status
|
|
0xe1 SL R/W 1 SCT Data Transfer
|
|
|
|
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
|
|
|
SMART Error Log Version: 1
|
|
ATA Error Count: 40 (device log contains only the most recent five errors)
|
|
CR = Command Register [HEX]
|
|
FR = Features Register [HEX]
|
|
SC = Sector Count Register [HEX]
|
|
SN = Sector Number Register [HEX]
|
|
CL = Cylinder Low Register [HEX]
|
|
CH = Cylinder High Register [HEX]
|
|
DH = Device/Head Register [HEX]
|
|
DC = Device Command Register [HEX]
|
|
ER = Error register [HEX]
|
|
ST = Status register [HEX]
|
|
Powered_Up_Time is measured from power on, and printed as
|
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|
|
|
Error 40 occurred at disk power-on lifetime: 409 hours (17 days + 1 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 50 d8 cc 40 Error: UNC at LBA = 0x00ccd850 = 13424720
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 00 08 4f d8 cc 40 00 00:00:49.139 READ DMA
|
|
c8 00 01 80 78 01 46 00 00:00:46.796 READ DMA
|
|
c8 00 01 76 16 71 42 00 00:00:45.832 READ DMA
|
|
c8 00 01 00 00 00 40 00 00:00:45.817 READ DMA
|
|
c8 00 01 00 00 00 40 00 00:00:53.464 READ DMA
|
|
|
|
Error 39 occurred at disk power-on lifetime: 409 hours (17 days + 1 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 50 d8 cc 40 Error: UNC at LBA = 0x00ccd850 = 13424720
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 00 08 4f d8 cc 40 00 00:00:49.139 READ DMA
|
|
c8 00 01 80 78 01 46 00 00:00:46.796 READ DMA
|
|
c8 00 01 76 16 71 42 00 00:00:45.832 READ DMA
|
|
c8 00 01 00 00 00 40 00 00:00:45.817 READ DMA
|
|
c8 00 01 00 00 00 40 00 00:00:45.817 READ DMA
|
|
|
|
Error 38 occurred at disk power-on lifetime: 409 hours (17 days + 1 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 50 d8 cc 40 Error: UNC at LBA = 0x00ccd850 = 13424720
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 00 08 4f d8 cc 40 00 00:00:42.553 READ DMA
|
|
c8 00 01 80 78 01 46 00 00:00:46.796 READ DMA
|
|
c8 00 01 76 16 71 42 00 00:00:45.832 READ DMA
|
|
c8 00 01 00 00 00 40 00 00:00:45.817 READ DMA
|
|
c8 00 01 00 00 00 40 00 00:00:45.817 READ DMA
|
|
|
|
Error 37 occurred at disk power-on lifetime: 409 hours (17 days + 1 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 50 d8 cc 40 Error: UNC at LBA = 0x00ccd850 = 13424720
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 00 08 4f d8 cc 40 00 00:00:42.553 READ DMA
|
|
ca 00 08 37 57 42 42 00 00:00:42.553 WRITE DMA
|
|
ca 00 08 5f 3a 42 42 00 00:00:42.540 WRITE DMA
|
|
ca 00 08 97 89 03 40 00 00:00:42.540 WRITE DMA
|
|
ca 00 08 47 25 03 40 00 00:00:42.514 WRITE DMA
|
|
|
|
Error 36 occurred at disk power-on lifetime: 409 hours (17 days + 1 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 00 50 d8 cc 40 Error: UNC at LBA = 0x00ccd850 = 13424720
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
c8 00 08 4f d8 cc 40 00 00:00:40.003 READ DMA
|
|
c8 00 08 47 d8 cc 40 00 00:00:40.003 READ DMA
|
|
c8 00 08 3f d8 cc 40 00 00:00:40.003 READ DMA
|
|
c8 00 08 37 d8 cc 40 00 00:00:40.003 READ DMA
|
|
c8 00 08 2f d8 cc 40 00 00:00:40.003 READ DMA
|
|
|
|
SMART Extended Self-test Log (GP Log 0x07) not supported
|
|
|
|
SMART Self-test log structure revision number 1
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Short offline Completed without error 00% 1 -
|
|
# 2 Short offline Completed without error 00% 1 -
|
|
# 3 Short offline Completed without error 00% 1 -
|
|
# 4 Short offline Completed without error 00% 1 -
|
|
# 5 Short offline Completed without error 00% 1 -
|
|
# 6 Short offline Completed without error 00% 1 -
|
|
# 7 Short offline Completed without error 00% 0 -
|
|
# 8 Short offline Completed without error 00% 0 -
|
|
# 9 Short offline Completed without error 00% 0 -
|
|
#10 Short offline Completed without error 00% 0 -
|
|
#11 Short offline Completed without error 00% 0 -
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Status Version: 2
|
|
SCT Version (vendor specific): 521 (0x0209)
|
|
Device State: Active (0)
|
|
Current Temperature: 32 Celsius
|
|
Power Cycle Min/Max Temperature: --/ 0 Celsius
|
|
Lifetime Min/Max Temperature: --/ 0 Celsius
|
|
|
|
SCT Data Table command not supported
|
|
|
|
SCT Error Recovery Control command not supported
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11)
|
|
ID Size Value Description
|
|
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
|
0x0001 2 0 Command failed due to ICRC error
|
|
0x0003 2 0 R_ERR response for device-to-host data FIS
|
|
0x0004 2 0 R_ERR response for host-to-device data FIS
|
|
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
|
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
|
|