smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: Western Digital Blue Mobile
|
|
Device Model: WDC WD10JPVX-60JC3T0
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 0014ee ...
|
|
Firmware Version: 01.01A01
|
|
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
|
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
|
Rotation Rate: 5400 rpm
|
|
Form Factor: 2.5 inches
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ACS-2 (minor revision not indicated)
|
|
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
|
Local Time is: Wed Oct 30 17:53:45 2024 UTC
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM level is: 128 (minimum power consumption without standby)
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
|
Wt Cache Reorder: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: (18600) seconds.
|
|
Offline data collection
|
|
capabilities: (0x51) SMART execute Offline immediate.
|
|
No Auto Offline data collection support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
No Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 209) minutes.
|
|
SCT capabilities: (0x703d) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 3
|
|
3 Spin_Up_Time POS--K 186 180 021 - 1691
|
|
4 Start_Stop_Count -O--CK 095 095 000 - 5414
|
|
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
|
7 Seek_Error_Rate POSR-K 100 253 051 - 0
|
|
9 Power_On_Hours -O--CK 052 052 000 - 35486
|
|
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
|
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
|
12 Power_Cycle_Count -O--CK 095 095 000 - 5223
|
|
183 Runtime_Bad_Block -O--CK 001 001 000 - 28260
|
|
184 End-to-End_Error PO--CK 100 100 097 - 0
|
|
187 Reported_Uncorrect -O--CK 100 099 000 - 1
|
|
188 Command_Timeout -O--CK 100 001 000 - 12885230958
|
|
190 Airflow_Temperature_Cel -O---K 069 045 040 - 31 (Min/Max 27/31)
|
|
191 G-Sense_Error_Rate -O--CK 001 001 000 - 1056
|
|
192 Power-Off_Retract_Count -O--CK 198 198 000 - 1614
|
|
193 Load_Cycle_Count -O--CK 030 030 000 - 511361
|
|
194 Temperature_Celsius -O---K 116 092 000 - 31
|
|
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
|
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
|
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
|
199 UDMA_CRC_Error_Count -O--CK 200 199 000 - 353
|
|
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 1
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 5 Comprehensive SMART error log
|
|
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 GPL R/O 1 Extended self-test log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x11 GPL R/O 1 SATA Phy Event Counters log
|
|
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
|
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
|
0xb7 GPL,SL VS 38 Device vendor specific log
|
|
0xbd GPL,SL VS 1 Device vendor specific log
|
|
0xc0 GPL,SL VS 1 Device vendor specific log
|
|
0xc1 GPL VS 93 Device vendor specific log
|
|
0xe0 GPL,SL R/W 1 SCT Command/Status
|
|
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
|
|
|
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
|
Device Error Count: 1
|
|
CR = Command Register
|
|
FEATR = Features Register
|
|
COUNT = Count (was: Sector Count) Register
|
|
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
|
LH = LBA High (was: Cylinder High) Register ] LBA
|
|
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
|
LL = LBA Low (was: Sector Number) Register ]
|
|
DV = Device (was: Device/Head) Register
|
|
DC = Device Control Register
|
|
ER = Error register
|
|
ST = Status register
|
|
Powered_Up_Time is measured from power on, and printed as
|
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|
|
|
Error 1 [0] occurred at disk power-on lifetime: 3634 hours (151 days + 10 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
10 -- 51 00 00 00 00 01 e9 f0 00 40 00 Error: IDNF at LBA = 0x01e9f000 = 32108544
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
61 00 90 00 f0 00 00 23 37 a0 f0 40 08 06:35:57.821 WRITE FPDMA QUEUED
|
|
61 00 78 00 e8 00 00 24 85 20 a8 40 08 06:35:57.821 WRITE FPDMA QUEUED
|
|
61 02 28 00 e0 00 00 03 21 65 d8 40 08 06:35:54.264 WRITE FPDMA QUEUED
|
|
61 01 90 00 d8 00 00 01 e9 f0 00 40 08 06:35:54.264 WRITE FPDMA QUEUED
|
|
61 00 01 00 d0 00 00 03 14 38 00 40 08 06:35:54.261 WRITE FPDMA QUEUED
|
|
|
|
SMART Extended Self-test Log Version: 1 (1 sectors)
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Short offline Completed without error 00% 35129 -
|
|
# 2 Short offline Completed without error 00% 1221 -
|
|
# 3 Short offline Completed without error 00% 1221 -
|
|
# 4 Extended offline Completed without error 00% 403 -
|
|
# 5 Short offline Completed without error 00% 400 -
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Status Version: 3
|
|
SCT Version (vendor specific): 258 (0x0102)
|
|
Device State: Active (0)
|
|
Current Temperature: 31 Celsius
|
|
Power Cycle Min/Max Temperature: 27/31 Celsius
|
|
Lifetime Min/Max Temperature: 0/55 Celsius
|
|
Under/Over Temperature Limit Count: 0/0
|
|
Vendor specific:
|
|
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
|
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
|
|
|
SCT Temperature History Version: 2
|
|
Temperature Sampling Period: 1 minute
|
|
Temperature Logging Interval: 1 minute
|
|
Min/Max recommended Temperature: 0/60 Celsius
|
|
Min/Max Temperature Limit: -41/85 Celsius
|
|
Temperature History Size (Index): 128 (57)
|
|
|
|
SCT Error Recovery Control:
|
|
Read: 85 (8.5 seconds)
|
|
Write: 85 (8.5 seconds)
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11)
|
|
ID Size Value Description
|
|
0x0001 2 0 Command failed due to ICRC error
|
|
0x0002 2 0 R_ERR response for data FIS
|
|
0x0003 2 0 R_ERR response for device-to-host data FIS
|
|
0x0004 2 0 R_ERR response for host-to-device data FIS
|
|
0x0005 2 0 R_ERR response for non-data FIS
|
|
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
|
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
|
0x0008 2 0 Device-to-host non-data FIS retries
|
|
0x0009 2 51 Transition from drive PhyRdy to drive PhyNRdy
|
|
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
|
0x000b 2 0 CRC errors within host-to-device FIS
|
|
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
|
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
|
0x8000 4 4771 Vendor specific
|
|
|