smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar SE Serial ATA
Device Model: WDC WD1600JS-23MHB0
Serial Number: --
Firmware Version: 03.01C03
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Wed Feb 8 19:05:27 2023 +04
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Write SCT (Get) Feature Control Command failed: Input/output error
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4980) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
Conveyance self-test routine
recommended polling time: ( 6) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 5
3 Spin_Up_Time PO---- 177 175 021 - 4125
4 Start_Stop_Count -O--CK 093 093 000 - 7453
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 084 084 000 - 12105
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 093 093 000 - 7379
190 Airflow_Temperature_Cel -O---K 067 044 045 Past 33
194 Temperature_Celsius -O---K 114 091 000 - 33
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 239
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 01 01 00 53 00 00 40 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 1e b0 8a f8 00 00 00 00 00 09 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 01 d5 00 e0 8a 1e 00 f8 b0 00 09 00 00:00:57.345 NOP [Reserved subcommand] [OBS-ACS-2]
00 22 b0 8a f8 00 01 00 00 00 09 00 00 1d+20:28:22.423 NOP [Reserved subcommand] [OBS-ACS-2]
00 01 d0 00 00 8a 1e 00 f8 b0 00 09 00 00:00:00.257 NOP [Reserved subcommand] [OBS-ACS-2]
Error 1 [0] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 01 01 00 53 00 00 00 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 97 b0 54 e1 00 00 00 00 00 09 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 01 d5 00 e0 54 96 00 e1 b0 00 09 00 00:00:57.345 NOP [Reserved subcommand] [OBS-ACS-2]
00 8b ec 54 e1 00 01 00 00 00 09 00 00 1d+19:29:17.708 NOP [Reserved subcommand] [OBS-ACS-2]
00 40 00 00 20 54 bd 00 db c8 00 09 00 00:00:00.001 NOP [Abort queued commands]
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 11867 -
# 2 Conveyance offline Completed without error 00% 11866 -
# 3 Short offline Completed without error 00% 11866 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: --/40 Celsius
Lifetime Min/Max Temperature: --/54 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/65 Celsius
Min/Max Temperature Limit: 1/60 Celsius
Temperature History Size (Index): 128 (32)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 154 Device-to-host register FISes sent due to a COMRESET
0x8000 4 160102 Vendor specific