smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Green
Device Model: WDC WD20EARX-00PASB0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 51.0AB51
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Feb 9 16:56:45 2021 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (39960) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 385) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 191 175 051 - 354020
3 Spin_Up_Time POS--K 173 163 021 - 6333
4 Start_Stop_Count -O--CK 088 088 000 - 12859
5 Reallocated_Sector_Ct PO--CK 199 199 140 - 44
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 001 001 000 - 72378
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1195
192 Power-Off_Retract_Count -O--CK 200 200 000 - 714
193 Load_Cycle_Count -O--CK 001 001 000 - 957453
194 Temperature_Celsius -O---K 117 091 000 - 33
196 Reallocated_Event_Count -O--CK 172 172 000 - 28
197 Current_Pending_Sector -O--CK 199 198 000 - 580
198 Offline_Uncorrectable ----CK 199 198 000 - 572
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 198 197 000 - 701
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 20565 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 20565 [20] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2c 89 38 40 00 Error: UNC at LBA = 0x7e2c8938 = 2116847928
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 30 00 00 7e 2c 89 38 40 08 11:38:06.699 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 11:38:06.699 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 11:38:06.699 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 11:38:06.692 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 11:38:06.692 SET FEATURES [Set transfer mode]
Error 20564 [19] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2c 89 38 40 00 Error: UNC at LBA = 0x7e2c8938 = 2116847928
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 a8 00 00 7e 2c 89 38 40 08 11:38:03.789 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 11:38:03.789 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 11:38:03.789 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 11:38:03.782 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 11:38:03.782 SET FEATURES [Set transfer mode]
Error 20563 [18] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2c 89 30 40 00 Error: UNC at LBA = 0x7e2c8930 = 2116847920
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 f8 00 00 7e 2c 89 30 40 08 11:38:00.873 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 11:38:00.873 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 11:38:00.873 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 11:38:00.866 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 11:38:00.866 SET FEATURES [Set transfer mode]
Error 20562 [17] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2c 89 30 40 00 Error: UNC at LBA = 0x7e2c8930 = 2116847920
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 e0 00 00 7e 2c 89 30 40 08 11:37:57.967 READ FPDMA QUEUED
60 00 08 00 d8 00 00 7e 2c 89 28 40 08 11:37:57.956 READ FPDMA QUEUED
60 00 08 00 d0 00 00 7e 2c 89 20 40 08 11:37:57.955 READ FPDMA QUEUED
60 00 08 00 c8 00 00 7e 2c 89 18 40 08 11:37:57.955 READ FPDMA QUEUED
60 00 08 00 c0 00 00 7e 2c 89 10 40 08 11:37:57.955 READ FPDMA QUEUED
Error 20561 [16] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2c 89 30 40 00 Error: UNC at LBA = 0x7e2c8930 = 2116847920
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 01 00 00 68 00 00 7e 2c 89 b0 40 08 11:37:55.017 READ FPDMA QUEUED
60 01 00 00 60 00 00 7e 2c 88 b0 40 08 11:37:55.011 READ FPDMA QUEUED
60 00 b0 00 58 00 00 7e 2c 88 00 40 08 11:37:55.010 READ FPDMA QUEUED
60 00 50 00 50 00 00 7e 25 07 b0 40 08 11:37:55.010 READ FPDMA QUEUED
60 01 00 00 48 00 00 7e 25 06 b0 40 08 11:37:55.007 READ FPDMA QUEUED
Error 20560 [15] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2e 76 b0 40 00 Error: UNC at LBA = 0x7e2e76b0 = 2116974256
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 e0 00 00 7e 2e 76 b0 40 08 11:37:44.069 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 11:37:44.069 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 11:37:44.069 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 11:37:44.062 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 11:37:44.062 SET FEATURES [Set transfer mode]
Error 20559 [14] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2e 76 b0 40 00 Error: UNC at LBA = 0x7e2e76b0 = 2116974256
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 90 00 00 7e 2e 76 b0 40 08 11:37:41.165 READ FPDMA QUEUED
60 00 08 00 88 00 00 7e 2e 76 a8 40 08 11:37:41.165 READ FPDMA QUEUED
60 00 08 00 80 00 00 7e 2e 76 a0 40 08 11:37:41.165 READ FPDMA QUEUED
60 00 08 00 78 00 00 7e 2e 76 98 40 08 11:37:41.165 READ FPDMA QUEUED
60 00 08 00 70 00 00 7e 2e 76 90 40 08 11:37:41.165 READ FPDMA QUEUED
Error 20558 [13] occurred at disk power-on lifetime: 6418 hours (267 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 7e 2e 76 b0 40 00 Error: UNC at LBA = 0x7e2e76b0 = 2116974256
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 01 00 00 c8 00 00 7e 2e 76 10 40 08 11:37:38.250 READ FPDMA QUEUED
60 01 00 00 c0 00 00 7e 2e 75 10 40 08 11:37:38.249 READ FPDMA QUEUED
60 01 00 00 b8 00 00 7e 2e 74 10 40 08 11:37:38.247 READ FPDMA QUEUED
60 01 00 00 b0 00 00 7e 2e 73 10 40 08 11:37:38.246 READ FPDMA QUEUED
60 01 00 00 a8 00 00 7e 2e 72 10 40 08 11:37:38.245 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 90% 58999 -
# 2 Short offline Aborted by host 90% 58998 -
# 3 Short offline Aborted by host 90% 58975 -
# 4 Short offline Aborted by host 90% 58878 -
# 5 Short offline Aborted by host 90% 58786 -
# 6 Short offline Aborted by host 90% 58759 -
# 7 Short offline Aborted by host 90% 58637 -
# 8 Short offline Aborted by host 90% 58629 -
# 9 Short offline Aborted by host 90% 58482 -
#10 Short offline Aborted by host 90% 58336 -
#11 Short offline Aborted by host 90% 58336 -
#12 Short offline Aborted by host 90% 58169 -
#13 Short offline Aborted by host 90% 58084 -
#14 Short offline Aborted by host 90% 58084 -
#15 Short offline Aborted by host 90% 58077 -
#16 Short offline Aborted by host 90% 58074 -
#17 Short offline Aborted by host 90% 58074 -
#18 Short offline Aborted by host 90% 58067 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 32/33 Celsius
Lifetime Min/Max Temperature: 0/59 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (131)
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 1336 Vendor specific