1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30
Files
2025-01-05 02:37:11 +03:00

101 lines
5.0 KiB
Plaintext

smartctl 7.2 2020-12-30 r5155 [OpenBSD 7.0 i386] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital VelociRaptor
Device Model: WDC WD3000HLFS-75G6U1
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 04.04V03
User Capacity: 300,069,052,416 bytes [300 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 10000 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Sun Jan 21 12:10:13 2024 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4680) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 58) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0003 202 198 021 Pre-fail Always - 2858
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 194
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x000e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 068 068 000 Old_age Always - 24069
10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 188
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 36
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 194
194 Temperature_Celsius 0x0022 105 079 000 Old_age Always - 42
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
240 Head_Flying_Hours 0x0032 069 069 000 Old_age Always - 23118
241 Total_LBAs_Written 0x0032 200 200 000 Old_age Always - 26604838154
242 Total_LBAs_Read 0x0032 200 200 000 Old_age Always - 70352200926
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 22798 -
# 2 Extended offline Aborted by host 90% 22771 -
# 3 Short offline Completed without error 00% 23 -
# 4 Short offline Interrupted (host reset) 90% 23 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.