1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30
Files
2021-05-18 23:01:35 +03:00

122 lines
4.9 KiB
Plaintext

smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-BETA3 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Raptor
Device Model: WDC WD360GD-00FLC0
Serial Number: --
Firmware Version: 33.08F33
User Capacity: 37,019,566,080 bytes [37.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
Local Time is: Thu Feb 25 15:58:19 2021 WIB
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Unknown SCT Status format version 1, should be 2 or 3.
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 957) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 21) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x001f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 200 200 051 - 0
3 Spin_Up_Time POS--- 118 116 021 - 2641
4 Start_Stop_Count -O--CK 100 100 040 - 717
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate PO-R-- 200 200 051 - 0
9 Power_On_Hours -O--CK 064 064 000 - 26386
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 698
194 Temperature_Celsius -O---K 119 101 000 - 28
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable -O--C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 2
200 Multi_Zone_Error_Rate P--R-- 200 179 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Unknown SCT Status format version 1, should be 2 or 3.
Unknown SCT Status format version 1, should be 2 or 3.
SCT (Get) Error Recovery Control command failed
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported