1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30
Files
2025-01-05 01:57:11 +03:00

314 lines
16 KiB
Plaintext

smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA (AF)
Device Model: WDC WD5000BPVT-00HXZT1
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01A01
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Sep 10 12:32:51 2024 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (13980) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 138) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 184 177 021 - 1758
4 Start_Stop_Count -O--CK 087 087 000 - 13029
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 199 000 - 0
9 Power_On_Hours -O--CK 066 066 000 - 25105
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 093 093 000 - 7182
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1242
193 Load_Cycle_Count -O--CK 119 119 000 - 244087
194 Temperature_Celsius -O---K 114 092 000 - 33
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 18
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 18 [17] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 30 00 00 00 6b 99 d0 40 00 00:03:30.106 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:29.124 SET FEATURES [Enable write cache]
60 00 08 00 28 00 00 00 6b 99 d0 40 00 00:03:26.210 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:25.291 SET FEATURES [Enable write cache]
60 00 08 00 20 00 00 00 6b 99 d0 40 00 00:03:22.314 READ FPDMA QUEUED
Error 17 [16] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 28 00 00 00 6b 99 d0 40 00 00:03:26.210 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:25.291 SET FEATURES [Enable write cache]
60 00 08 00 20 00 00 00 6b 99 d0 40 00 00:03:22.314 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:21.332 SET FEATURES [Enable write cache]
60 00 08 00 18 00 00 00 6b 99 d0 40 00 00:03:18.418 READ FPDMA QUEUED
Error 16 [15] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 20 00 00 00 6b 99 d0 40 00 00:03:22.314 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:21.332 SET FEATURES [Enable write cache]
60 00 08 00 18 00 00 00 6b 99 d0 40 00 00:03:18.418 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:17.436 SET FEATURES [Enable write cache]
60 00 08 00 10 00 00 00 6b 99 d0 40 00 00:03:14.522 READ FPDMA QUEUED
Error 15 [14] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 18 00 00 00 6b 99 d0 40 00 00:03:18.418 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:17.436 SET FEATURES [Enable write cache]
60 00 08 00 10 00 00 00 6b 99 d0 40 00 00:03:14.522 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:13.540 SET FEATURES [Enable write cache]
60 00 08 00 08 00 00 00 6b 99 d0 40 00 00:03:10.626 READ FPDMA QUEUED
Error 14 [13] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 10 00 00 00 6b 99 d0 40 00 00:03:14.522 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:13.540 SET FEATURES [Enable write cache]
60 00 08 00 08 00 00 00 6b 99 d0 40 00 00:03:10.626 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:09.644 SET FEATURES [Enable write cache]
60 00 08 00 f8 00 00 00 6b 99 d0 40 00 00:03:06.730 READ FPDMA QUEUED
Error 13 [12] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 08 00 00 00 6b 99 d0 40 00 00:03:10.626 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:09.644 SET FEATURES [Enable write cache]
60 00 08 00 f8 00 00 00 6b 99 d0 40 00 00:03:06.730 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:05.748 SET FEATURES [Enable write cache]
60 00 08 00 f0 00 00 00 6b 99 d0 40 00 00:03:02.834 READ FPDMA QUEUED
Error 12 [11] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 f8 00 00 00 6b 99 d0 40 00 00:03:06.730 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:05.748 SET FEATURES [Enable write cache]
60 00 08 00 f0 00 00 00 6b 99 d0 40 00 00:03:02.834 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:01.852 SET FEATURES [Enable write cache]
60 00 08 00 e8 00 00 00 6b 99 d0 40 00 00:02:58.954 READ FPDMA QUEUED
Error 11 [10] occurred at disk power-on lifetime: 8420 hours (350 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 6b 99 d0 40 00 Error: UNC at LBA = 0x006b99d0 = 7051728
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 f0 00 00 00 6b 99 d0 40 00 00:03:02.834 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:03:01.852 SET FEATURES [Enable write cache]
60 00 08 00 e8 00 00 00 6b 99 d0 40 00 00:02:58.954 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 a0 00 00:02:58.954 SET FEATURES [Enable write cache]
60 00 08 00 e0 00 00 00 6b 99 d0 40 00 00:02:56.040 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 29/36 Celsius
Lifetime Min/Max Temperature: 29/54 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (99)
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 11199 Vendor specific