mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
329 lines
16 KiB
Plaintext
329 lines
16 KiB
Plaintext
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-BETA5 amd64] (local build)
|
|
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: Western Digital Black Mobile
|
|
Device Model: WDC WD5000LPLX-60ZNTT1
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 0014ee ...
|
|
Firmware Version: 02.01A02
|
|
User Capacity: 500,107,862,016 bytes [500 GB]
|
|
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
|
Rotation Rate: 7200 rpm
|
|
Form Factor: 2.5 inches
|
|
Device is: In smartctl database 7.3/5528
|
|
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
|
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
|
Local Time is: Wed Jul 31 23:38:34 2024 EAT
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM level is: 128 (minimum power consumption without standby)
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, frozen [SEC2]
|
|
Wt Cache Reorder: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 25) The self-test routine was aborted by
|
|
the host.
|
|
Total time to complete Offline
|
|
data collection: ( 6720) seconds.
|
|
Offline data collection
|
|
capabilities: (0x51) SMART execute Offline immediate.
|
|
No Auto Offline data collection support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
No Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 79) minutes.
|
|
SCT capabilities: (0x303d) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
|
3 Spin_Up_Time POS--K 143 141 021 - 1825
|
|
4 Start_Stop_Count -O--CK 071 071 000 - 29298
|
|
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
|
7 Seek_Error_Rate POSR-K 200 195 051 - 0
|
|
9 Power_On_Hours -O--CK 086 086 000 - 10827
|
|
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
|
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
|
12 Power_Cycle_Count -O--CK 097 097 000 - 3880
|
|
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
|
184 End-to-End_Error PO--CK 100 100 097 - 0
|
|
187 Reported_Uncorrect -O--CK 100 099 000 - 2
|
|
188 Command_Timeout -O--CK 100 099 000 - 4295032833
|
|
190 Airflow_Temperature_Cel -O---K 063 048 040 - 37 (Min/Max 37/37)
|
|
191 G-Sense_Error_Rate -O--CK 001 001 000 - 6493
|
|
192 Power-Off_Retract_Count -O--CK 200 200 000 - 479
|
|
193 Load_Cycle_Count -O--CK 111 111 000 - 268785
|
|
194 Temperature_Celsius -O---K 106 091 000 - 37
|
|
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
|
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
|
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
|
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
|
200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 1
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 5 Comprehensive SMART error log
|
|
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 GPL R/O 1 Extended self-test log
|
|
0x09 SL R/W 1 Selective self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x11 GPL R/O 1 SATA Phy Event Counters log
|
|
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
|
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
|
0xb7 GPL,SL VS 37 Device vendor specific log
|
|
0xbd GPL,SL VS 1 Device vendor specific log
|
|
0xc0 GPL,SL VS 1 Device vendor specific log
|
|
0xc1 GPL VS 93 Device vendor specific log
|
|
0xe0 GPL,SL R/W 1 SCT Command/Status
|
|
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
|
|
|
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
|
Device Error Count: 23
|
|
CR = Command Register
|
|
FEATR = Features Register
|
|
COUNT = Count (was: Sector Count) Register
|
|
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
|
LH = LBA High (was: Cylinder High) Register ] LBA
|
|
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
|
LL = LBA Low (was: Sector Number) Register ]
|
|
DV = Device (was: Device/Head) Register
|
|
DC = Device Control Register
|
|
ER = Error register
|
|
ST = Status register
|
|
Powered_Up_Time is measured from power on, and printed as
|
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|
|
|
Error 23 [22] occurred at disk power-on lifetime: 7463 hours (310 days + 23 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 00 00 00 0a a1 26 a0 40 00 Error: UNC at LBA = 0x0aa126a0 = 178333344
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 40 00 60 00 00 0a a1 26 a0 40 00 00:03:12.582 READ FPDMA QUEUED
|
|
60 00 20 00 58 00 00 0a a1 7b c0 40 00 00:03:12.342 READ FPDMA QUEUED
|
|
60 00 20 00 50 00 00 0a a1 5b c0 40 00 00:03:12.334 READ FPDMA QUEUED
|
|
60 00 40 00 48 00 00 0a a1 9c 80 40 00 00:03:12.313 READ FPDMA QUEUED
|
|
60 00 20 00 40 00 00 0a a1 9c 20 40 00 00:03:12.266 READ FPDMA QUEUED
|
|
|
|
Error 22 [21] occurred at disk power-on lifetime: 6089 hours (253 days + 17 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
40 -- 51 00 01 00 00 0a 40 58 f8 40 00 Error: UNC at LBA = 0x0a4058f8 = 171989240
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
60 00 f8 00 18 00 00 0a 40 5b f8 40 00 02:54:38.762 READ FPDMA QUEUED
|
|
60 01 00 00 10 00 00 0a 40 5a f8 40 00 02:54:38.762 READ FPDMA QUEUED
|
|
60 01 00 00 08 00 00 0a 40 59 f8 40 00 02:54:38.762 READ FPDMA QUEUED
|
|
60 01 00 00 f8 00 00 0a 40 58 f8 40 00 02:54:38.762 READ FPDMA QUEUED
|
|
60 00 88 00 f0 00 00 0a 40 58 70 40 00 02:54:38.753 READ FPDMA QUEUED
|
|
|
|
Error 21 [20] occurred at disk power-on lifetime: 4 hours (0 days + 4 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:04:56.484 SANITIZE DEVICE
|
|
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:04:56.484 SECURITY FREEZE LOCK
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:04:56.452 READ DMA EXT
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:04:56.452 READ DMA EXT
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:04:56.452 READ DMA EXT
|
|
|
|
Error 20 [19] occurred at disk power-on lifetime: 4 hours (0 days + 4 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:02.196 SANITIZE DEVICE
|
|
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.196 SECURITY FREEZE LOCK
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:02.167 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 00:00:02.167 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 00:00:02.167 READ DMA EXT
|
|
|
|
Error 19 [18] occurred at disk power-on lifetime: 4 hours (0 days + 4 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 03:30:10.212 SANITIZE DEVICE
|
|
f5 00 00 00 00 00 00 00 00 00 00 e0 00 03:30:10.211 SECURITY FREEZE LOCK
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 03:30:10.185 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 03:30:10.185 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 03:30:10.185 READ DMA EXT
|
|
|
|
Error 18 [17] occurred at disk power-on lifetime: 4 hours (0 days + 4 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 03:24:16.053 SANITIZE DEVICE
|
|
f5 00 00 00 00 00 00 00 00 00 00 e0 00 03:24:16.053 SECURITY FREEZE LOCK
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 03:24:12.560 READ DMA EXT
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 03:24:12.560 READ DMA EXT
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 03:24:12.560 READ DMA EXT
|
|
|
|
Error 17 [16] occurred at disk power-on lifetime: 4 hours (0 days + 4 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 03:10:43.505 SANITIZE DEVICE
|
|
f5 00 00 00 00 00 00 00 00 00 00 e0 00 03:10:43.505 SECURITY FREEZE LOCK
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 03:10:43.475 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 03:10:43.475 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 03:10:43.475 READ DMA EXT
|
|
|
|
Error 16 [15] occurred at disk power-on lifetime: 3 hours (0 days + 3 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|
-- -- -- == -- == == == -- -- -- -- --
|
|
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 02:27:29.432 SANITIZE DEVICE
|
|
f5 00 00 00 00 00 00 00 00 00 00 e0 00 02:27:29.432 SECURITY FREEZE LOCK
|
|
25 00 00 00 01 00 00 00 00 00 00 e0 00 02:27:29.402 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 02:27:29.402 READ DMA EXT
|
|
25 00 00 00 01 00 00 39 f8 38 00 e0 00 02:27:29.402 READ DMA EXT
|
|
|
|
SMART Extended Self-test Log Version: 1 (1 sectors)
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Short offline Aborted by host 90% 9902 -
|
|
# 2 Short offline Completed without error 00% 8188 -
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Status Version: 3
|
|
SCT Version (vendor specific): 258 (0x0102)
|
|
Device State: Active (0)
|
|
Current Temperature: 37 Celsius
|
|
Power Cycle Min/Max Temperature: 37/37 Celsius
|
|
Lifetime Min/Max Temperature: 15/52 Celsius
|
|
Under/Over Temperature Limit Count: 0/0
|
|
Vendor specific:
|
|
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
|
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
|
|
|
SCT Temperature History Version: 2
|
|
Temperature Sampling Period: 1 minute
|
|
Temperature Logging Interval: 1 minute
|
|
Min/Max recommended Temperature: 0/60 Celsius
|
|
Min/Max Temperature Limit: -41/85 Celsius
|
|
Temperature History Size (Index): 128 (8)
|
|
|
|
SCT Error Recovery Control:
|
|
Read: 85 (8.5 seconds)
|
|
Write: 85 (8.5 seconds)
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11)
|
|
ID Size Value Description
|
|
0x0001 2 0 Command failed due to ICRC error
|
|
0x0002 2 0 R_ERR response for data FIS
|
|
0x0003 2 0 R_ERR response for device-to-host data FIS
|
|
0x0004 2 0 R_ERR response for host-to-device data FIS
|
|
0x0005 2 0 R_ERR response for non-data FIS
|
|
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
|
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
|
0x0008 2 0 Device-to-host non-data FIS retries
|
|
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
|
|
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
|
0x000b 2 0 CRC errors within host-to-device FIS
|
|
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
|
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
|
0x8000 4 500 Vendor specific
|
|
|