smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
|
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: Intel X25-E SSDs
|
|
Device Model: SSDSA2SH032G1SB INTEL
|
|
Serial Number: --
|
|
LU WWN Device Id: 5 001517 ...
|
|
Firmware Version: 845C8862
|
|
User Capacity: 32,000,000,000 bytes [32.0 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: Solid State Device
|
|
TRIM Command: Unavailable
|
|
Device is: In smartctl database 7.3/5319
|
|
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
|
SATA Version is: SATA 2.6, 3.0 Gb/s
|
|
Local Time is: Fri May 20 13:45:30 2022 CDT
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
AAM feature is: Unavailable
|
|
APM feature is: Unavailable
|
|
Rd look-ahead is: Enabled
|
|
Write cache is: Enabled
|
|
DSN feature is: Unavailable
|
|
ATA Security is: Disabled, frozen [SEC2]
|
|
Wt Cache Reorder: Unavailable
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 1) seconds.
|
|
Offline data collection
|
|
capabilities: (0x75) SMART execute Offline immediate.
|
|
No Auto Offline data collection support.
|
|
Abort Offline collection upon new
|
|
command.
|
|
No Offline surface scan supported.
|
|
Self-test supported.
|
|
Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Conveyance self-test routine
|
|
recommended polling time: ( 1) minutes.
|
|
|
|
SMART Attributes Data Structure revision number: 5
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|
3 Spin_Up_Time ------ 100 000 000 - 0
|
|
4 Start_Stop_Count ------ 100 000 000 - 0
|
|
5 Reallocated_Sector_Ct -O---- 100 100 000 - 0
|
|
9 Power_On_Hours -O---- 100 100 000 - 61124
|
|
12 Power_Cycle_Count -O---- 100 100 000 - 245
|
|
192 Unsafe_Shutdown_Count -O---- 100 100 000 - 154
|
|
232 Available_Reservd_Space PO---- 100 100 010 - 0
|
|
233 Media_Wearout_Indicator -O---- 099 099 000 - 0
|
|
225 Host_Writes_32MiB ------ 200 200 000 - 250355
|
|
226 Intel_Internal -O---- 255 000 000 - 0
|
|
227 Intel_Internal -O---- 000 000 000 - 0
|
|
228 Intel_Internal -O---- 000 000 000 - 0
|
|
||||||_ K auto-keep
|
|
|||||__ C event count
|
|
||||___ R error rate
|
|
|||____ S speed/performance
|
|
||_____ O updated online
|
|
|______ P prefailure warning
|
|
|
|
General Purpose Log Directory Version 0
|
|
SMART Log Directory Version 1 [multi-sector log support]
|
|
Address Access R/W Size Description
|
|
0x00 GPL,SL R/O 1 Log Directory
|
|
0x01 SL R/O 1 Summary SMART error log
|
|
0x02 SL R/O 8 Comprehensive SMART error log
|
|
0x03 SL R/O 1 Ext. Comprehensive SMART error log
|
|
0x06 SL R/O 1 SMART self-test log
|
|
0x07 SL R/O 1 Extended self-test log
|
|
0x10 GPL R/O 1 NCQ Command Error log
|
|
0x4d GPL - 1 Reserved
|
|
0x80-0x9f SL R/W 16 Host vendor specific log
|
|
0xff GPL - 65024 Reserved
|
|
|
|
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
|
|
|
SMART Error Log Version: 1
|
|
No Errors Logged
|
|
|
|
SMART Extended Self-test Log (GP Log 0x07) not supported
|
|
|
|
SMART Self-test log structure revision number 1
|
|
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|
# 1 Short offline Completed without error 00% 61123 -
|
|
# 2 Extended offline Completed without error 00% 43146 -
|
|
# 3 Conveyance offline Completed without error 00% 43146 -
|
|
# 4 Short offline Completed without error 00% 43146 -
|
|
|
|
SMART Selective self-test log data structure revision number 0
|
|
Note: revision number not 1 implies that no selective self-test has ever been run
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|
|
SCT Commands not supported
|
|
|
|
Device Statistics (GP/SMART Log 0x04) not supported
|
|
|
|
Pending Defects log (GP Log 0x0c) not supported
|
|
|
|
SATA Phy Event Counters (GP Log 0x11) not supported
|
|
|