mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
128 lines
6.4 KiB
Plaintext
128 lines
6.4 KiB
Plaintext
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.7] (local build)
|
|
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Device Model: JAJS600M512C
|
|
Serial Number: --
|
|
Firmware Version: S0719A0
|
|
User Capacity: 512,110,190,592 bytes [512 GB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: Solid State Device
|
|
Form Factor: 2.5 inches
|
|
Device is: Not in smartctl database [for details use: -P showall]
|
|
ATA Version is: ACS-3 T13/2161-D revision 4
|
|
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
|
Local Time is: Sun May 24 13:05:48 2020 CEST
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART Status not supported: Incomplete response, ATA output registers missing
|
|
SMART overall-health self-assessment test result: PASSED
|
|
Warning: This result is based on an Attribute check.
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x00) Offline data collection activity
|
|
was never started.
|
|
Auto Offline Data Collection: Disabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: ( 120) seconds.
|
|
Offline data collection
|
|
capabilities: (0x11) SMART execute Offline immediate.
|
|
No Auto Offline data collection support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
No Offline surface scan supported.
|
|
Self-test supported.
|
|
No Conveyance Self-test supported.
|
|
No Selective Self-test supported.
|
|
SMART capabilities: (0x0002) Does not save SMART data before
|
|
entering power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 10) minutes.
|
|
|
|
SMART Attributes Data Structure revision number: 1
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
|
1 Raw_Read_Error_Rate 0x0032 100 100 050 Old_age Always - 0
|
|
5 Reallocated_Sector_Ct 0x0032 100 100 050 Old_age Always - 0
|
|
9 Power_On_Hours 0x0032 100 100 050 Old_age Always - 226
|
|
12 Power_Cycle_Count 0x0032 100 100 050 Old_age Always - 86
|
|
160 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 0
|
|
161 Unknown_Attribute 0x0033 100 100 050 Pre-fail Always - 100
|
|
163 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 10
|
|
164 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 3433
|
|
165 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 19
|
|
166 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 5
|
|
167 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 11
|
|
168 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 2000
|
|
169 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 100
|
|
175 Program_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0
|
|
176 Erase_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0
|
|
177 Wear_Leveling_Count 0x0032 100 100 050 Old_age Always - 0
|
|
178 Used_Rsvd_Blk_Cnt_Chip 0x0032 100 100 050 Old_age Always - 0
|
|
181 Program_Fail_Cnt_Total 0x0032 100 100 050 Old_age Always - 0
|
|
182 Erase_Fail_Count_Total 0x0032 100 100 050 Old_age Always - 0
|
|
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 35
|
|
194 Temperature_Celsius 0x0022 100 100 050 Old_age Always - 47
|
|
195 Hardware_ECC_Recovered 0x0032 100 100 050 Old_age Always - 0
|
|
196 Reallocated_Event_Count 0x0032 100 100 050 Old_age Always - 0
|
|
197 Current_Pending_Sector 0x0032 100 100 050 Old_age Always - 0
|
|
198 Offline_Uncorrectable 0x0032 100 100 050 Old_age Always - 0
|
|
199 UDMA_CRC_Error_Count 0x0032 100 100 050 Old_age Always - 0
|
|
232 Available_Reservd_Space 0x0032 100 100 050 Old_age Always - 100
|
|
241 Total_LBAs_Written 0x0030 100 100 050 Old_age Offline - 90351
|
|
242 Total_LBAs_Read 0x0030 100 100 050 Old_age Offline - 5062
|
|
245 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 86307
|
|
|
|
SMART Error Log Version: 1
|
|
Warning: ATA error count 0 inconsistent with error log pointer 1
|
|
|
|
ATA Error Count: 0
|
|
CR = Command Register [HEX]
|
|
FR = Features Register [HEX]
|
|
SC = Sector Count Register [HEX]
|
|
SN = Sector Number Register [HEX]
|
|
CL = Cylinder Low Register [HEX]
|
|
CH = Cylinder High Register [HEX]
|
|
DH = Device/Head Register [HEX]
|
|
DC = Device Command Register [HEX]
|
|
ER = Error register [HEX]
|
|
ST = Status register [HEX]
|
|
Powered_Up_Time is measured from power on, and printed as
|
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|
|
|
Error -4 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
00 00 00 00 00 00 00 at LBA = 0x00000000 = 0
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
61 40 30 50 95 00 40 00 00:00:00.000 WRITE FPDMA QUEUED
|
|
60 40 88 90 eb ca 40 00 00:00:00.000 READ FPDMA QUEUED
|
|
61 40 28 10 5f 36 40 00 00:00:00.000 WRITE FPDMA QUEUED
|
|
ec 00 01 00 00 00 00 00 00:00:00.000 IDENTIFY DEVICE
|
|
ec 00 01 00 00 00 00 00 00:00:00.000 IDENTIFY DEVICE
|
|
|
|
SMART Self-test log structure revision number 1
|
|
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|
|
|
Selective Self-tests/Logging not supported
|
|
|
|
|
|
|